background image

Roofmaster STEC non-insulated version - Installation and maintenance

11

FläktGroup DC_10082GB_20180213_R1

Specifications are subject to alteration without notice

 

EC Declaration of Conformity 

 

Machinery Directive 2006/42/EC, Annex II, sub A

 

 
 

 
Manufacturer:  

Fläkt Woods Oy 

 
Address: 

 

Kalevantie 39 

 

 

FI-20520 Turku, Finland 

 
 
Name and address of the person authorised to compile the relevant technical documentation: 
 
Name: 

 

Heikki Stenberg 

Address: as above 

 
 
Confirms that: 
 
 

 

STEC roof fan with accessories and including  

 

 

Electronically commutated external rotor motor with integrated controller 

 

 

 

is in accordance with the Machinery Directive (2006/42/EC)  
 
 
 
And that the machinery is in conformity with the provisions of the following other Directives: 
 
 

 

EMC Directive 2014/30/EU 

 

 

Low Voltage Directive 2014/35/EU 

 

 

ErP Directive 2009/125/EC 

 
 
 
And furthermore, declares that 
 

the following (parts/clauses of) European harmonised standards and 
Regulations have been applied: EN ISO 12100:2010, EN ISO 13857:2008, EN 
60204-1, EN 61000-6,-2,-3 and Regulations 327/2011 and 1253/2014. 

 
 
This Declaration of Conformity is valid only if the installation is done in accordance with the Machinery 
Directive 2006/42/EC, where appropriate, and that the original accessories are used. 
 
 
 

 

 

 

 

 

 

 

 

Turku, 8.9.2017 

 

Heikki Stenberg 

 

 

 

 

R&D Manager 

 

 

8 DECLARATION OF CONFORMITY

Summary of Contents for Roofmaster STEC 190

Page 1: ...ROOF FAN ROOFMASTER STEC NON INSULATED VERSION INSTALLATION AND MAINTENANCE...

Page 2: ...y regulations Tools and protective equipment necessary for preventing accidents from occurring while installing and operating the fan must be used worn in accordance with the local safety regulations...

Page 3: ...225 630 3 2 APPLICATIONS Roof fans are used as exhaust fans in ventilation systems The maximum allowed rotational speed for fan motor combination is shown in the technical catalogue Note If the fan i...

Page 4: ...WEIGHTS Htot W1 W2 245 W3 1112 775 853 W5 1069 775853 W5 12 12 W4 Fan size W1 W2 W3 W4 W5 Htot Weight kg 190 358 348 1 130 8 225 467 469 442 398 368 234 10 310 467 469 442 398 368 314 16 355 577 579...

Page 5: ...he product 4 2 TRANSPORT SAFETY The transport material is to be selected according to the packag ing and the weight of the product Loading must be carried out as instructed 4 3 INTERMEDIATE STORAGE If...

Page 6: ...3 Place the mounting frame on the base frame roof curb and fasten it with bolts If the base frame is made of concrete use anchor bolts There are four 12 mm holes eight 12 mm in size 630 for bolts in t...

Page 7: ...In case of electrical accessories all required instructions are in cluded in the delivery 5 4 1 THE FAN WITH SAFETY SWITCH INSTALLED AT THE COMMISSIONING PHASE 1 Fasten the safety switch in proper pl...

Page 8: ...roof fan does not need any special service However it is necessary to clean the fan impeller especially when the air is not clean This helps to avoid vibrations in the impeller If there is an abnorma...

Page 9: ...ff the fan from the isolator and wait 5 minutes before starting the maintenance work 2 Open the fixing bolts after that the fan casing can be lifted open The fan shall be locked to open position with...

Page 10: ...from the base frame 7 Remove the motor bolts if necessary protect motorized impel ler from dropping down and lift the motor bracket away 8 Remove the inlet cone fastened with pop rivets and sealing c...

Page 11: ...th integrated controller is in accordance with the Machinery Directive 2006 42 EC And that the machinery is in conformity with the provisions of the following other Directives EMC Directive2014 30 EU...

Page 12: ...y application area We offer our customers innovative technologies high quality and outstanding performance supported by more than a century of accumulated industry experience The widest product range...