15
|
Page
INTERNAL CERAMIC GLASS REMOVAL
Follow the procedures below to remove and install the internal ceramic glass (double glass fireplace configuration).
Note: Suction cups are needed to remove the glass.
Warning!
Turn off the fireplace and allow time for the unit to cool before attempting to remove the glass.
CAUTION
:
The ceramic glass is very fragile and should be handled with care.
CAUTION
: Do not operate the appliance with glass removed, cracked, or broken. Replacement of the panel(s) should
be done by a licensed or qualified service person.
Step 1
–
Attach glass suction cups to the glass. Remove the glass’
lower magnetic trim
. Place the trim in a secure
place. Any unit above 45” requires 2 suction cups to hold the glass.
Step 2
–
Release the
lower glass trim
. The lower trim bolts can be released by hand and should not require any tools.
Once bolts are released remove lower glass holder trim.
Step 3
–
Hold the glass suction cups and hand release trim bolt on the top. The trim does not need to be removed and
will only open to allow a gap for glass removal.
Step 4
–
Push the glass up and clear it from the bottom as shown.
When putting the glass back, DO NOT overtighten the bolts or glass may break.
Step 1
Step 2