54
|
Page
ADJUSTMENTS
If necessary, adjust the low-pressure regulator to match the appliance rating. for factory-set nominal outlet pressure and
adjustment range.
a. Remove pressure regulator adjustment cap and screw.
b. Using screwdriver, turn inner adjustment screw clockwise to increase or counterclockwise to decrease gas pressure to main
burner.
c. Always replace cap screw and tighten firmly to ensure proper operation.
Have the gas supply line installed in accordance with local codes, if any. If not available, follow ANSI 223.1.
Installation should be done by a qualified installer approved and/or licensed as required by the locality (
in the Commonwealth
of Massachusetts installation must be performed by a licensed plumber or gas fitter
).
USING A REDUCER TO DE -RATE YOUR FLARE FIREPLACE
Output (Burner) Adjustment Pressure by unscrewing this
screw and rotate the inner (plastic) screw CW or CCW
for adjustment
Honeywell Valve Adjustment