DOUBLE GLASS BOARD & LED LIGHT GUIDE
FAN BYPASS SWITCHES & LEDs
(***NUMBER OF FANS CAN CHANGE BASED ON MODEL SIZE***)
The dipswitches (DSW1&DSW2), in the “FAN BYPASS” area of the Double Glass Board, are used to determine what fans will
be monitored by the board, verifying all fans are indeed working properly before allowing the fireplace burner to start. Turn
the switch ON ↑(UP) to bypass monitoring of fan number of your choice, & OFF ↓(DOWN) to begin to monitor fan activity. If
no fan is present, set switch to on so it will bypass the need to verify fan activity. The switches are numbered to correlate with
the LED lights they are associated with above.
The third Dipswitch is the “Master Bypass (PV, Relay, Fan)” dipswitch. Representing 4 switches 1
-3 are used and the 4th switch
is not used.
Switch 1: is used to det
ermine if the system has PV or not, Turn the switch ON ↑(UP) to bypass monitoring of PV system, &
OFF ↓(DOWN) to begin to monitor PV system.
Switch 2: is used to Bypass the relay to the Board so that the board will begin work directly when get 110v no matter if the
system has relay or not, Turn the switch ON ↑(UP) to bypass the relay, & OFF ↓(DOWN) to wait for relay command from the
user.
Switch 3: representing the master Bypass for all, turning this ON↑ bypasses all check to the fan system & Power Vent, OFF↓
will monitor the whole system.
Switch 4: is not used.
FAN LED INDICATORS
A.
Red
- Fan is not connected or malfunctioning.
B.
Off - Fan is being bypassed.
C.
Green
- Fan is running properly.