3.5 Swimming Pool Heat Pumps Electrical Wiring 

NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it simply 
prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect
you against short circuits inside the unit. Bonding is also required.

3.INSTALLATION AND CONNECTION

3.6 Initial startup of the Unit  

circulate water through the heat exchanger.

Start up Procedure - After installation is completed, you should follow these steps: 

1. Turn on your filter pump. Check for water leaks and verify flow to and from the pool.
2. Turn on the electrical power supply to the unit, then press the key ON/OFF of wire 
    controller, It should start in  several seconds.
3. After running a few minutes make sure the air leaving the top(side) of the unit is cooler
   (Between 5-10 ℃)
4. With the unit operating turn the filter pump off. The unit should also turn off 
    automatically, 
5. Allow the unit and pool pump to run 24 hours per day until desired pool water
    temperature is reached. When the water-in temperature reach setting, The unit just 
    shuts off. The unit  will now automatically restart (as long as your pool pump is running)
     when the pool temperature drops more than 2℃below set temperature.  

Water Flow Switch

 - the unit is equipped with a flow switch that turns it on when the pool 

pump is running and shuts it off when the pump shuts off. This switch is the same type used 
in all gas pool heaters and is factory adjusted for normal pool installations. If the pool 
water level is more than a few feet above or below the thermostat knob of the unit, your 
dealer may need to adjust it at initial startup. 

Time Delay

- The unit is equipped with a 3 minute built-in solid state restart delay included 

to protect control circuit components and to eliminate restart cycling and contactor 
chatter. This time delay will automatically restart the unit approximately 3 minutes after
each control circuit interruption. Even a brief power interruption will activate the solid 
state 3 minute restart delay and prevent the unit from starting until the 5 minute countdown
is completed. Power interruptions during the delay period will have no effect on the 3 
minute countdown. 

NOTE- In order for the unit to heat the pool or spa, the filter pump must be running to 

7

The unit has a separate molded-in junction box with a standard electrical conduit nipple already 
in place. Just remove the screws and the front panel, feed your supply lines in through the conduit 
nipple and wire-nut the electric supply wires to the three connections  already in the junction box 
(four connections  if three phase). To complete electrical hookup, connect Heat Pump by electrical
conduit, UF cable or other suitable means as specified (as permitted by local electrical authorities) 
to a dedicated AC power supply branch circuit equipped with the proper circuit breaker, 
disconnect or time delay fuse protection. 

Disconnect - A disconnect means (circuit breaker , fused or un-fused switch) should be located
within sight of and readily accessible from the uni, This is common practice on commercial and 
residential air conditioners and heat pumps. It prevents remotely-energizing unattended equipment
 and permits turning off power at the unit while the unit is being serviced. 

3.4 Swimming Pool Heat Pumps Plumbing 

The Swimming Pool Heat Pumps exclusive full flow titanium heat exchanger 
requires no special plumbing arrangements or bypass. The water pressure drop is 
less than 10kPa  at max. Flow rate. Since there is no residual heat or flame 
temperatures, The unit does not need copper heat sink piping. PVC pipe can be run 
straight into the unit.

Location: Connect the unit in the pool pump discharge (return) line 
downstream of all filter and pool pumps, and upstream of any chlorinators, 
ozonators or chemical pumps.

Standard model have slip glue fittings which accept  40mm NB
PVC pipe for connection to the pool or spa filtration piping. By using a 
50 NB to 40NB you can plumb 50NB PVC piping straight into the unit. 

Give serious consideration to adding a quick coupler fitting at the unit inlet and outlet 
to allow easy draining of unit for winterizing and to provide easier access should 
servicing be required. 

Condensation: Since the Heat pump cools down the air about 4 -5

, water 

may condense on the fins of the horseshoe shaped evaporator. If the relative 
humidity is very high, this could be as much as several litres an hour. The water 
will run down the fins into the basepan and drain out through the barbed plastic 
condensation drain fitting on the side of the basepan. This fitting is designed to 
accept 3/4" clear vinyl tubing which can be pushed on by hand and run to a suitable 
drain. It is easy to mistake the condensation for a water leak inside the unit. 

NB: A quick way to verify that the water is condensation is to shut off the 
unit  and keep the pool pump running. If the water stops running out of the 
basepan, it is condensation. AN EVEN QUICKER WAY IS to TEST THE DRAIN 
WATER FOR CHLORINE - if the is no chlorine present, then it's condensation. 

3.INSTALLATION AND CONNECTION

6

To  pool

From pump

PVC COUPLER
RECOMMENDED(Provided)

CONDENSATION
DRAIN
BARB FTG

Summary of Contents for KP-017

Page 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual ...

Page 2: ...ol Heat Pumps Plumbing 6 3 5 Swimming Pool Heat Pumps Electrical Wiring 7 3 6 Initial Start up of the Unit 7 4 Usage and Operation 8 4 1 The Functions of the LCD Controller 8 4 2 How to Set Operation Parameter 8 4 3 To Choose Mode 9 4 4 How to know the Current Status 9 4 5 Operation Data Setting 10 5 Maintenance and Inspection 11 5 1 Maintenance 11 5 2 Trouble Shooting Guide 11 6 Appendix 12 6 1 C...

Page 3: ...ool Heat Pump Unit heats the swimming pool water and keeps the temperature constant This type of pump has the following characteristics 1 Durable The heat exchanger is made of PVC titanium tube which can withstand prolonged exposure to corrosives such as chlorine 2 Installation flexibility The unit can be installed outdoors or indoors 3 Quiet operation The unit comprises an effi cient rotary scrol...

Page 4: ...ion Compre sso r motor solenoid valve four way valve capacit or condenser heater or electri cal cable are defecti ve Ambient temp Sensor failure The sensor is open or short circuit Check or change the sensor The sensor is open or short circuit Check or change the sensor The sensor is open or short circuit Check or change the sensor Compressor over current Compressor is over load Check the electric...

Page 5: ...s open 1 30 seconds start before compressors starting 30 seconds stop after compressors stopping water pump stops when water temperature setting temperature factory setting 0 20 45 7 15 F0 150min 3min 95 7 1 1 1 4 4 Operation data setting 2 SPECIFICATION 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 21 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 40 41 42 30 10 20 31 1 Front panel 15 Power cor d...

Page 6: ... power on unit Under running the LCD displays the water setting temp water out temp and current mode Press to set temp 1 degree higher press to set temp 1 degree lower 4 4 How to know the current status Water outlet temp Ambient temp compressor exhaust temp M M M Condenser temp Under running press 3s to check the current status of the unit You can check water out ambient compressor condenser tempe...

Page 7: ...ool filter piping The unit may be installed virtually anywhere outdoors For indoor pools consult the supplier Unlike a gas heater it has no draft or pilot light problem in a windy area DO NOT place the unit in an enclosed area with a limited air volume where the units discharge air will be re circulated DO NOT place the unit to shrubs which can block air inlet These locations deny the unit of a co...

Page 8: ...gh the conduit nipple and wire nut the electric supply wires to the three connections already in the junction box four connections if three phase To complete electrical hookup connect Heat Pump by electrical conduit UF cable or other suitable means as specified as permitted by local electrical authorities to a dedicated AC power supply branch circuit equipped with the proper circuit breaker discon...