ENTER End
*/
$
%
ENT
*
*
ZEND
*
107
7-6 Standby Time
This function enables to set the duration time to turn off the main power of the
scanner after scanning LED turns off.
*
8122
*
0 ~ 99 sec
1 sec
5 sec
(A) Scan “Enter” barcode
(B) Scan “Standby Time” barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
If configuration is 10 sec, the
parameter value is
10 sec / 1 sec =
10
Note: this configuration is only applicable when the scanner is in USB
cable mode.
7-7 LED Off Delay
When the barcode is successfully read and decoded, The Green LED indicator
will be shown; user can configure the duration time for LED indicator. (
Note:
when the configuration set as “0” or “00”, the Green LED will be always
ON
)
*
8192
*
0 ~ 2.5 sec
0.01 sec
0.2 sec
7- 7 LED OFF Delay
7. General Configuration Setting
7- 6 Standby Time
7- 7 LED OFF Delay
Configuration Range
Unit
Default Setting
Procedure:
Example:
Configuration Range
Unit
Default Setting