ENTER End
*/
$
%
ENT
*
*
ZEN
D
*
69
6-1-8 Ext Transmission Delay
This configuration enables the delay time (time gap) setting in between each
barcode data sending to PC.
*
7042
*
(A) Scan “Enter” barcode
(B) Scan Ext Transmission Delay
barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
if configure to 1 sec.
the parameter value is:
1 sec / 0.01
sec = 100.
6-1-9 Lamp Off Delay
The configuration enables the setting of duration time of scanner LED power
off.
*
7052
*
(A) Scan “Enter” barcode
(B) Scan “LampOff Delay” barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “Set“ barcode
(E) Scan “End” barcode
If configuration is10 sec, the
parameter value is
10 sec / 1 sec
= 10.
.
0 ~ 2.5 Sec
0.01 sec
0 sec
6. Memory / Bluetooth General Setting
6-1-8 Ext Transmission Delay
6-1-9 Lamp Off Delay
Configuration Range
Unit
Default Setting
0 ~ 2.5 Sec
0.01 sec
0 sec
Procedure:
Example:
Configuration Range
Unit
Default Setting
Procedure:
Example: