The connection is performed using
power cable with PowerCon connector
( i n c l u d e d ) . Th e d e v i ce m u s t b e
operated by qualified personnel.
5.2 Voltage specification
Input Voltage
Total Power
Frequency
110/230V
150W
50/60Hz
5.3 Connecting power supply
CAUTION!
In the case of cable damage do not attempt to repair.
Replacement or repair can be made only on the manufacturer or by
a person with appropriate permissions.
Make sure that the power grid supply
parameters are consistent with device
parameters and limitations are not
exceeded.
User Manual
•
Instrukcja Obsługi
DMX
Controller
DMX 512
DMX 512
5.1 Connecting DMX signal
The connection is performed using cable
with XLR-female -> XLR-Male plugs.
5. CONNECTION
The device is equipped with the following
interfaces:
1. DMX (in/out): XLR 3(5)-pin socket
2. Power (in/out): powerCON socket
1
3
2
2
FEMALE
XLR
GROUND
DMX +
DMX -
MALE
XLR
3
1
CAUTION!
At the last fixture, the DMX signal has to be terminated with a terminator.
Solder a 120Ω resistor between signal (-) and signal (+) into a XLR plug and plug it in the
DMX output of the last fixture.
1
FEMALE
XLR
GROUND
DMX +
DMX -
MALE
XLR
2
3
4
5
1
2
3
4 5
3-pin XLR
5-pin XLR
Auto Mode:
Set Address 10 OFF, Set Address
9 OFF. Address 1 to 8are 8 effect, can select
one or more to play.
Sound Mode:
Set
Address 10 OFF, Set Address 9 ON. Address
1 to 8are 8 effect, can select one or more to
play.
DMX512 Mode:
Set Address 10 ON, Address
1to9 is between 1-511
Slave Mode:
Set Address 1 and 10 ON,
Address 2-9 OFF. (same as DMX512
address 1.) System has 23 DMX512
Channels, have 22 DMX512 Channels
without step motor.
System has 2 Gobos, each gobo with 11
DMX512 channels. The detailed channels
as following: