SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a
registered engineer.
This is a condition of the Flavel extended guarantee
schemes.
The service should include
changing the oxypilot as a condition of the
guarantee
and visually checking the chimney and fire opening for accumulations
of debris and a smoke test to check for a positive up-draught in the chimney.
The condition of the coals should be checked and
if necessary the whole set
should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of
access.
After any servicing work a gas tightness check must always be
carried out.
Remote Control Fires - For Diagrams refer to section 2
4.1
Removing the RC Burner Assembly
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the trim. Lift the fender and ash pan cover out of the way and
put them in a safe location. Isolate the gas supply. Remove the glass
panel, unscrewing the top and side retaining brackets, see page 10 &
11 of this manual for information. Carefully lift clear the glass panel.
Remove the coals, front ceramic from the rail and fuel-bed base matrix.
Remove all of the loose coals and front ceramic rail. Unscrew the two
pozi-drive fixing screws which secure the burner heat shield and
remove it from the fire.
4.1.4
Unscrew the 4 off burner retaining screws on the side brackets, the
burner should then be lifted out of the firebox.
NOTE
: Please take care with the wiring loom
4.1.5
To refit the burner assembly, re-assemble in reverse order and carry out
a gas tightness test. Refit the burner heat shield then refit the coals
referring to section 3 for the correct coal layout. Refit the glass panel
and glass panel retaining trims. The fender and ash pan cover or fascia
can now be re-positioned.
28