SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a
GAS SAFE registered engineer and must include a thermocouple change.
This is a condition of the Flavel guarantee schemes that this is
carried out by a competent person i.e a GAS SAFE registered Engineer in
accordance with these servicing notes.
The condition of the logs should be checked and
if necessary the whole set
should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of
access.
After any servicing work a gas tightness check must always be
carried out.
4.1
Removing the Burner Assembly from the Stove
4.1.1
Ensure the stove is cool, open the door.
4.1.2
Isolate the gas supply, then remove the ceramics. Remove
the 2 off fixing screws which hold the fuel-bed support plate in position
as shown below in figure 30 then lift the fuel-bed support clear from the
stove.
Fig. 30
31
Fuel-bed support plate fixing screws