Fig. 12
5.4.4
Store the glass frame assembly in a safe place.
5.4.5
Re-assemble in reverse order when re-fitting the glass assembly.
Ensure that the glass assembly is correctly located on the top
flange of the combustion chamber, this can be achieved by putting
your hand onto the top edge of the glass frame inside the
convection air aperture and pushing down firmly to check the
glass frame is correctly located.
DO NOT OPERATE THE FIRE WITHOUT THE GLASS FRAME
ASSEMBLY IN POSITION OR NOT CORRECTLY LOCATED.
44
R/H edge of glass frame