116
Equipment
SECTION SIX
Electrical Connections:
• Inspect and clean all hydraulic pump electrical
connections every 12 months . If corrosion is
evident, spray with WD-40 or equivalent .
MANUAL OVERRIDE
Check the following items
before
attempting
to
manually retract the jacks .
• Engine is running .
• Transmission is in
park .
• Park brake is applied .
• 15 Amp in line fuse
next
to
hydraulic
pump tests good .
If after verifying these conditions and the jacks will not
retract, the jacks can be retracted manually . It will be
necessary to access the hydraulic pump and control
valves .
Control Valve Identification:
Each control valve operates a designated jack identified
by the color of wire to the control valve:
• Green wire is the front jack .
• Red wire is the right rear jack .
• Blue wire is the left rear jack .
Manually Retracting the Jacks:
• Turn off disconnect switches to chassis and house
batteries .
• Locate respective control valve per corresponding
jack .
• Insert 1/8” Allen wrench into control valve and turn
inwards (clockwise) .
• Access manual drive coupler on motor located
beneath label or plug .
• Attach a standard hex bit into an angle drill .
• Insert bit into drive motor coupler .
• Run drill counterclockwise to retract .
• When the jack is retracted, turn control valve(s)
outward (counterclockwise) to lock jack in up
position .
• Turn on both chassis and house disconnect
switches .
• Take the motorhome to an authorized repair center .
FANS
POWER ROOF VENT
The vent is opened or closed by turning the crank knob
in the desired direction . The vent is for ventilation only,
it is not designed to cool the motorhome .
Fan Operation:
• Battery disconnect switch must be on .
• Battery switch, by entry door, must be on .
• Fan is activated by pushing the vent power switch
on .
• Vent must be opened before using the fan .
CAUTION:
Do not continue to run the hydraulic motor if the
jacks do not retract . Damage to the motor can
occur .
To Hydraulic Pump
To Control Panel
15 AMP
Fuse
090517ka
NOTE:
Jack control valve location in the manifold will vary
slightly depending on number of slideout rooms
operated by the hydraulic system .
Control Valve
(right rear leg – red wire)
Control Valve
(left rear leg –
blue wire)
Breather Cap
(to fill reservoir)
Rear of Hydraulic Pump
090517d
Representation of the Hydraulic Jack Manifold
NOTE:
Some control valves have a knurled knob instead
of an Allen socket .
Summary of Contents for Class A Gas 2020
Page 173: ...FLEETWOOD RV CLASS A GAS 2020 OWNER S MANUAL 171...
Page 174: ...172 Notes...