Safety instructions
2.4 General warning notices
M3302-01en
Edition 09/2022
19
Max. ambient temperature
Max. surface temperature
Vibratory torque
1)
80 °C
120 °C
T
KW perm
= 0.3 • T
KW catalogue data
Table 2-3:
Maximum surface temperature (TX) for an explosive atmosphere as a result of dust/air mixtures
1)
Observe the reduced vibratory torques if you are using the coupling in a potentially explosive atmosphere. The supplier of
the assembly is responsible for calculating the vibratory torque load.
Notes concerning operation of the coupling in potentially explosive atmospheres
• Only use the coupling underground in mines in potentially explosive atmospheres to-
gether with drive motors that can be switched off in the event of the formation of an ex-
plosive atmosphere.
• Earth machines that are connected via the coupling with a leakage resistance of less
than 10
6
Ω.
• If you want to use a coated coupling in potentially explosive atmospheres, please note
the requirements concerning the conductivity of the paint and the limitation on the paint
layer thickness applied in accordance with EN 80079-36. No build-up of electrostatic
charges is to be expected with a paint layer thickness of less than 200 μm.
• Only use TAPER clamping bushes with parallel key in potentially explosive atmo-
spheres. Insert the screws for fastening the TAPER clamping bushes with liquid screw
locking agent. If you are not using an original FlenderTAPER clamping bush, make sure
that the TAPER clamping bush you are using fully meets the technical requirements.
2.4
General warning notices
2.4 General warning notices
DANGER
Danger if the coupling fractures
The coupling may burst if it is not used for its intended use. There is a risk of fatal injury
from flying fragments. Bursting of the coupling can lead to an explosion in potentially ex-
plosive atmospheres.
•
Use the coupling for the purpose for which it is intended.
DANGER
Risk of explosion when using coupling parts without Ex marking
Coupling parts without Ex marking have not been approved for use in potentially explosive
atmospheres. These coupling parts can lead to an explosion during operation.
•
Only use couplings with Ex marking in potentially explosive atmospheres.
DANGER
Danger
Risk of injury due to the use of unsuitable and/or damaged components. The use of unsuit-
able and/or damaged components can lead to an explosion in potentially explosive atmo-
spheres.
•
Observe the information regarding conditions of use.
Summary of Contents for ELPEX-S
Page 6: ...Table of contents 6 Edition 09 2022 M3302 01en ...
Page 8: ...List of tables 8 Edition 09 2022 M3302 01en ...
Page 10: ...List of figures 10 Edition 09 2022 M3302 01en ...
Page 14: ...Introduction 1 4 Copyright 14 Edition 09 2022 M3302 01en ...
Page 22: ...Description 22 Edition 09 2022 M3302 01en Structure ...
Page 38: ...Assembling 5 3 Aligning the coupling 38 Edition 09 2022 M3302 01en ...
Page 40: ...Commissioning 40 Edition 09 2022 M3302 01en ...
Page 46: ...Operation 7 2 Fault causes and correction 46 Edition 09 2022 M3302 01en ...
Page 56: ...Service and support 9 1 Contact 56 Edition 09 2022 M3302 01en ...