5.1 Preparatory work
M3302-01en
Edition 09/2022
31
Selection of the set screw
CAUTION
Physical injury
Danger of injury from protruding set screw.
•
Please observe the information about selecting the set screw.
As set screws use threaded studs in accordance with ISO 4029 with a toothed cup point.
The size of the set screw is determined by the bore made. The set screw should fill out the
tapped hole as much as possible and must not protrude beyond the hub.
5.1.4
Balancing the coupling
5.1 Preparatory work
Notes on balancing the coupling
NOTICE
Damage to coupling part 1 (1) or 2 (2)
If you completely drill through the flange on coupling part 1 (1) or 2 (2), then coupling
part 1 (1) or 2 (2) is no longer allowed to be used for operation.
•
Please observe the stipulations about machining the balancing bore.
Please note the following when balancing the coupling:
• Select the balancing quality according to the application (but at least G16 in accordance
with DIN ISO21940).
• Observe the balancing specification according to DIN ISO21940-32.
• Machine the balancing bore on a large radius with adequate clearance to the holes and
the outer contour.
Figure 5-3:
Position of the balancing bore for single-plane balancing
①
Part 1 and/or 2
②
Balancing bore
Summary of Contents for ELPEX-S
Page 6: ...Table of contents 6 Edition 09 2022 M3302 01en ...
Page 8: ...List of tables 8 Edition 09 2022 M3302 01en ...
Page 10: ...List of figures 10 Edition 09 2022 M3302 01en ...
Page 14: ...Introduction 1 4 Copyright 14 Edition 09 2022 M3302 01en ...
Page 22: ...Description 22 Edition 09 2022 M3302 01en Structure ...
Page 38: ...Assembling 5 3 Aligning the coupling 38 Edition 09 2022 M3302 01en ...
Page 40: ...Commissioning 40 Edition 09 2022 M3302 01en ...
Page 46: ...Operation 7 2 Fault causes and correction 46 Edition 09 2022 M3302 01en ...
Page 56: ...Service and support 9 1 Contact 56 Edition 09 2022 M3302 01en ...