Installation
15
4.
Lower the Clamp Lever fully so that the stationary part and the moveable clamp are firmly
together.
5.
To verify clamping, attempt to remove the folded paper. If the paper cannot be removed,
the center stationary part and moveable clamp have proper clamping. If the paper can be
pulled out, adjust both the bottom and top eccentrics to provide proper clamping for this
area.
6.
Raise the Clamp Lever fully and remove the paper.
7.
The bottom eccentric is shown at the right
(the top is
identical in purpose and procedure)
. Loosen the M6
Screw so that the 15mm Hex Head eccentric can be
turned.
8.
Slide the folded paper between the bottom
stationary part and the moveable clamp.
9.
Lower the Clamp Lever fully so that the stationary
part and the moveable clamp are firmly together.
10. Turn the eccentric left or right while attempting to
remove the paper from between the stationary part
and the moveable clamp.
11. To verify clamping, attempt to remove the folded
paper. When the paper cannot be removed, the
eccentric is providing proper clamping. Tighten the
M6 Screw so that the eccentric will not turn.
12. Raise the Clamp Lever fully and remove the paper.
13. The adjustment for the bottom eccentric is complete.
14. Repeat Steps 7 – 13 for the upper eccentric.
15. The adjustments for the eccentrics are completed. All three clamping areas now provide
proper material clamping.