DD 2G 10.8-LD
20
Charger
The CA 10.8 charger is designed to charge
FLEX batteries of the following types
– AP 10.8/2.5,
– AP 10.8/4.0 and
– AP 10.8/6.0.
1
Insertion slot for battery
2
Contacts
3
LED fault message (red)
4
LED charge status (green)
5
Ventilation slots
6
Power cord with mains plug
Displays of LED
Charging process
CAUTION!
Insert only original batteries in the supplied
charger.
Insert the charger mains plug.
The LED fault message and the LED
charge status light up for a short time.
Insert battery into the charger as far as
stop.
The LED charge status flashes and the
battery is charged.
When the battery is fully charged, the
LED charge status is lit continuously.
Remove the battery from the charger.
Pull out the mains plug.
Fault messages
If the LED fault message lights up after the
battery is inserted into the charger, there is
an fault with the battery or charger.
The LED warning message is lit up
continuously:
– The battery is too hot or too cold.
The charging process starts when the
battery reaches the charging tempera-
ture (0°C...40°C).
The LED fault message flashes or none of
the two LEDs lights up:
– Remove battery from the charger.
Check contacts at charger and battery
for contamination and clean if necessary.
Reinsert battery. The battery is faulty
if the same display appears again.
Replace battery or have it checked in
a professional workshop.
red
green
off
flashes Battery is charging.
off
on
Charging process finished.
Maintenance charging.
See “Charging process”.
flashes
off
Battery is too hot or too
cold.
on
off
Battery or charger is faulty.
See “Fault messages”.