ST 1005 VE
13
Noise and vibration
The noise and vibration values have been
determined in accordance with EN 60745.
The A evaluated noise level of the power tool
is typically:
Total vibration value (when grinding metal
surfaces):
=
t^okfkd>
qÜÉ=áåÇáÅ~íÉÇ=ãÉ~ëìêÉãÉåíë=êÉÑÉê=íç=åÉï=
éçïÉê=íççäëK=a~áäó=ìëÉ=Å~ìëÉë=íÜÉ=åçáëÉ=~åÇ=
îáÄê~íáçå=î~äìÉë=íç=ÅÜ~åÖÉK
klqb
The vibration emission level given in this infor-
mation sheet has been measured in accordance
with a standardised test given in EN 60745 and
may be used to compare one tool with another.
It may be used for a preliminary assessment of
exposure. The declared vibration emission level
represents the main applications of the tool.
However if the tool is used for different applica-
tions, with different accessories or poorly main-
tained, the vibration emission may differ.
This may significantly increase the exposure level
over the total working period.
For a precise estimation of the vibration load
the times should also be considered during which
the power tool is switched off or even running, but
not actually in use. This may significantly decrease
the exposure level over the total working period.
Identify additional safety measures to protect
the operator from the effects of vibration such as:
maintain the tool and the accessories, keep the
hands warm, organisation of work patterns.
`^rqflk>
tÉ~ê=É~ê=éêçíÉÅíáçå=~í=~=ëçìåÇ=éêÉëëìêÉ=
~ÄçîÉ=UR=Ç_E^FK
Technical specifications
Sound pressure
L
pA
[dB(A)]
Sound power
L
WA
[dB(A)]
ST 1005 VE
83
94
Uncertainty K = 3 dB
Emission value a
h
[m/s
2
]
ST 1005 VE
7.3
Uncertainty
K [m/s
2
]
1.5
Machine type
Finger sander
ST 1005 VE
Grinding tool
mm
39 x 60
Mains voltage
V/Hz
230/50
Power input
W
400
Power output
W
220
No load stroke rate
r.p.m.
1200–4500
Stroke
mm
8
Protection class
/II
Weight (without power cord)
kg
2.2