background image

18

 

MHCP Primary Cleaner

Section 7 – Troubleshooting

Problem

Possible Cause

Possible Solutions

Poor cleaning 

performance

Cleaner under-tensioned

Adjust to correct tension – see spring length/kPa chart

Cleaner over-tensioned

Adjust to correct tension – see spring length/kPa chart

Cleaner installed in wrong location

Verify "C" dimension, relocate to correct dimension

Cleaner blade worn or damaged

Replace cleaner blade

Rapid Blade Wear

Tension on cleaner too high/low

Adjust to correct tension – see spring length/kPa chart

Cleaner not located correctly

Check cleaner location for correct dimensions

Blade attack angle incorrect

Check cleaner location for correct dimensions

Material too abrasive for blade

Option: switch to alternate cleaner with metal blades

Mechanical splice damaging blade

Repair, skive or replace splice

Centre wear on blade 

(smile effect)

Blade wider than material path

Replace blade with width to match material path

Tension on cleaner too high/low

Adjust to correct tension – see spring length/kPa chart

Unusual wear or 

damage to blade

Mechanical splice damaging blade

Repair, skive or replace splice

Belt damaged or ripped

Repair or replace belt

Cleaner not correctly located

Verify "C" dimension, relocate to correct dimension

Damage to pulley or pulley lagging

Repair or replace pulley

Vibration or noise

Cleaner not located correctly

Verify "C" dimension, relocate to correct dimension

Blade attack angle incorrect

Verify "C" dimension, relocate to correct dimension

Cleaner running on empty belt

Use a spray pole when the belt is empty

Cleaner tension too high/low

Adjust to correct tension or slight adjust to diminish

Cleaner locking bolts not secure

Check and tighten all bolts and nuts

Cleaner not square to head pulley

Verify "C" dimension, relocate to correct dimension

Material buildup in chute

Clean up build-up on cleaner and in chute

Cleaner being pushed 

away from pulley

Cleaner tension not set correctly

Ensure correct tension/increase tension slightly

Sticky material is overburdening cleaner

Increase tension; replace with cleaner with metal tips; 

replace with larger size cleaner

Cleaner not set up correctly

Confirm location dimensions are equal on both sides

Summary of Contents for MHCP

Page 1: ...MHCP Primary Cleaner Installation Operation and Maintenance Manual www flexco com www flexco com...

Page 2: ...Purchased From _____________________________________________________________ Installation Date _____________________________________________________________ This information will be helpful for any fu...

Page 3: ...ation Checklist and Testing 12 5 1 Pre Op Checklist 12 5 2 Test Run the Conveyor 12 Section 6 Maintenance 13 6 1 New Installation Inspection 13 6 2 Routine Visual Inspection 13 6 3 Routine Physical In...

Page 4: ...11 608 4180 Visit www flexco com for other Flexco locations and products Please read this manual thoroughly and pass it on to any others who will be directly responsible for installation operation an...

Page 5: ...ps Clear the conveyor belt or clamp securely in place Use Personal Protective Equipment PPE Safety eyewear Hardhats Safety footwear Close quarters springs and heavy components create a worksite that c...

Page 6: ...sure all the parts are included Review the Tools Needed list on the top of the installation instructions Check the conveyor site Will the cleaner be installed on a chute Are there obstructions that ma...

Page 7: ...em In the example we decide to lower the pole 50mm to clear the support structure 2 Write down known dimensions We can now determine two of the three required dimension which will allow us to find the...

Page 8: ...650 330 365 492 675 343 365 502 700 356 365 511 725 368 365 518 750 381 365 527 775 394 365 537 800 406 365 546 825 419 365 556 850 432 365 565 875 445 365 575 900 457 365 584 925 470 365 594 950 483...

Page 9: ...and locking bolts on one side facing down and on the adjoining side facing away from the head pulley Fig 4 Leave the locking bolts loose 4 1 MHCP Primary Cleaner cont mark Y X mark Center large templa...

Page 10: ...orque arm until the pivot rod is against the end of the slot nearest the pole Tighten the locking bolts and jam nuts on the torque arm Fig 12S NOTE The torque arm should be up against the mounting bas...

Page 11: ...ulator of Washer orque Arm Measure from top of washer to top of torque arm 13S Setthecorrectbladetension Refertothe chartorthedecalonthemountingbase forthespringlengthrequiredforthebelt width Lightlyp...

Page 12: ...ure that all installation materials and tools have been removed from the belt and the conveyor area 5 2 Test Run the Conveyor Run the conveyor for at least 15 minutes and inspect the cleaning performa...

Page 13: ...n or if there are areas that are dirty If the blade is worn out and needs to be replaced If there is damage to the blade or other cleaner components If fugitive material is built up on the cleaner or...

Page 14: ...2 Remove the worn blade cartridge Remove two bolts on each end of cartridge and remove the cartridge from the pole Fig 2 Clean all fugitive material from the pole NOTE If cartridge is hard to remove u...

Page 15: ...e Align holes and install bolts washers and nuts Fig 4 Locking Bolts And Jam Nuts Collapse Air Bags of Washer orque Arm Measure from top of washer to top of torque arm Fig 5 6 del eje y se debe extend...

Page 16: ...__ Service Quote ___________________ Activity ______________________________________________________________________________________ _____________________ Date ___________________ Work done by _______...

Page 17: ...s No Pole Condition Good Bent Worn Lagging Side Lag Ceramic Rubber Other None Condition of lagging Good Bad Other_ _______________________________________________________ Cleaner s Overall Performance...

Page 18: ...spring length kPa chart Unusual wear or damage to blade Mechanical splice damaging blade Repair skive or replace splice Belt damaged or ripped Repair or replace belt Cleaner not correctly located Ver...

Page 19: ...ng wear Available for Belt Widths 600 to 2100 mm Other sizes available upon request CEMA Cleaner Rating Class 5 Maximum Overall Pole Length Maximum Conveyor Span Centre Pole Length Top of washer to to...

Page 20: ...HART Diameter X Y C 500 254 365 445 525 267 365 451 550 279 365 460 575 292 365 467 600 305 365 476 625 318 365 483 650 330 365 492 675 343 365 502 700 356 365 511 725 368 365 518 750 381 365 527 775...

Page 21: ...30P 78724 MHP CP30 75962 MHCP 2BC30 76639 36 900 94 2380 5 MHCP 36P 78725 MHP CP36 75963 MHCP 2BC36 76640 42 1050 100 2530 6 MHCP 42P 78726 MHP CP42 75964 MHCP 2BC42 76488 48 1200 106 2680 7 MHCP 48P...

Page 22: ...1200mm PSTS W 75898 0 8 10a Tension Spring Silver 1 ea for belts 1350 2100mm PSTS S 75899 1 4 11 Bushing Kit 2 ea for White Silver Tensioners QMTBK W 76098 0 1 12 Pole Bearing Assy for cleaners shipp...

Page 23: ...PA30 75946 54 9 900 36 MHCP BPA36 75947 61 8 1050 42 MHCP BPA42 75948 68 6 1200 48 MHCP BPA48 75949 75 4 1350 54 MHCP BPA54 75950 82 3 1500 60 MHCP BPA60 75951 89 1 1800 72 MHCP BPA72 75952 102 8 2100...

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ...the tail pulley Exclusive blade design quickly spirals debris off the belt Economical and easy to service Available in vee or diagonal models PT Max Belt Trainer Belt Ploughs Limited space cleaners f...

Page 28: ...rldwide through superior service and innovation 236 Albert Amon Rd Meadowdale Ext 7 Germiston 1614 South Africa Tel 27 11 608 4180 Fax 27 11 454 5821 E mail flexco flexco co za Visit www flexco com fo...

Reviews: