Flexel Ecofloor Cable Kit 

 

Installation instructions 

 

Please read these notes carefully and follow the instruction guidelines shown in this booklet 
as they will ensure optimum, safe performance and m ay also affect the validity of the 
guarantee provided. If in any doubt consult your supplier or the manufacturer. 
 
Planning the installation. 
 
1). Measuring up. 
2). Floor preparation. 
3). Marking out. 
4). Laying the Cable. 
5). Install Thermostat and Floor probe 
5). ‘Add On’ Cables for larger areas. 
6). Final testing. 
7). Switching on. 
 

1). Measuring up. 

 
It is important to measure the room  correctly and avoid all permanent fixtures such as baths, 
showers, kitchen and bedroom units, (rem ember also that it is important to avoid thermally 
blocking the heated area as this will result in localised heat build up and possible subsequent 
damage to the floor covering. Allowing for perimeter clearance deduct a further 5% to r each 
the actual available heated floor area. 
 

Output requirements. 

 
Apart from timber floors where 100 W /m² output is recommended, install the optimum  heat 
level possible for the available floor area. 
Referring to the tables shown below the cable spacings can be varied to achieve differing 
heat levels.  
 

160 W/m²  for optimum output 

130 W/m²  f or comfort heating and 
100 W/m²  f or background heating (Recomm ended for timber floors). 

Flexel

 Installation Manual

Cable Kit Instructions

Summary of Contents for Ecofloor

Page 1: ...d all permanent fixtures such as baths showers kitchen and bedroom units remember also that it is important to avoid thermally blocking the heated area as this will result in localised heat build up a...

Page 2: ...0 8 1 9 3 10 5 11 8 13 0 41 EK 101700 1700 10 6 11 9 13 1 15 1 17 0 31 EK 102000 2000 12 5 14 4 16 2 18 1 20 0 26 EK 102300 EK1700 AD600 2300 14 3 15 9 17 7 20 0 23 0 23 EK102600 EK2000 AD600 2600 16...

Page 3: ...marked and scaled drawing your supplier will calculate the appropriate kit required 2 Floor preparation Cable kits can be laid onto most existing floor surfaces that are sound and suitably prepared A...

Page 4: ...quired and the electrical supply position form a channel in the floor adjacent to this point as illustrated THERMOSTAT SUPPLIED 45mm RECESSE D MOUNTING BOX REQUIRED FOR FLUSH MOUNTING 230VOLT SUPPLY F...

Page 5: ...t again If you have ordered the wrong size of kit contact your supplier Now and referring to the tables on page 1 test the cable circuit for continuity resistance using an ohmeter Avoid traffic over t...

Page 6: ...6 Flexel Installation Manual Cable Kit Instructions Finished Floor Diagrams Cross Section Flexible adhesive Tile finished with flexible grout...

Page 7: ...att cable 5 9m2 coverage Lay the additional cable and if necessary adjust the spacing to achieve full floor coverage The thermostat sensor must be positioned centrally between cable loops Tiling the f...

Page 8: ...440 multicoat for wet areas Mira 4800 antifire fluid primer Mira X Plan self Levelling acrylic and Fibre reinforced levelling compound Mira 3250 superplan Fix acrylic reinforced cement based quick cur...

Page 9: ...tching on Before switching on the underfloor heating allow a minimum of 3 days for natural drying of the tile adhesive and grout Initially operate the system for 2 3 hours per day increasing to full c...