Table of cable kit sizes. 

 
 

EK 10200

200

1.2

1.4

1.6

1.8

2.0

264

EK 10250

250

1.6

1.8

2.0

2.3

2.5

212

EK 10320

320

2.0

2.3

2.6

2.9

3.2

165

EK 10400

400

2.5

2.9

3.2

3.6

4.0

132

EK 10450

450

2.8

3.2

3.6

4.1

4.5

118

EK 10600

600

3.7

4.3

4.8

5.4

6.0

88

EK 10750

750

4.7

5.4

6.1

6.8

7.5

70

EK 10950

950

5.9

6.8

7.7

8.6

9.5

56

EK 101100

1100

6.9

7.9

8.9

10.0

11.0

48

EK 101300

1300

8.1

9.3

10.5

11.8

13.0

41

EK 101700

1700

10.6

11.9

13.1

15.1

17.0

31

EK 102000

2000

12.5

14.4

16.2

18.1

20.0

26

EK 102300
(AD600)

2300

14.3

15.9

17.7

20.0

23.0

23

EK102600
(AD600)

2600

16.2

17.9

20.0

22.6

26.0

20

EK102950
(AD950)

2950

18.4

20.3

22.7

25.7

29.5

18

EK103300
(AD1300)

3300

20.6

22.8

25.4

28.7

33.0

16

EK103700
(AD1700)

3700

23.1

25.5

28.5

32.2

37.0

14

Code

Output

Heated Floor area coverage(m²)

Resistance

(Watts)

Cable spacing - cm and heat output(w/

(160)

(145)

(130)

(115)

(100)

m²)

(ohms)

7

8

9

10

11

 

Flexel

 Installation Manual

Cable Kit Instructions

Summary of Contents for Ecofloor

Page 1: ...d all permanent fixtures such as baths showers kitchen and bedroom units remember also that it is important to avoid thermally blocking the heated area as this will result in localised heat build up a...

Page 2: ...0 8 1 9 3 10 5 11 8 13 0 41 EK 101700 1700 10 6 11 9 13 1 15 1 17 0 31 EK 102000 2000 12 5 14 4 16 2 18 1 20 0 26 EK 102300 EK1700 AD600 2300 14 3 15 9 17 7 20 0 23 0 23 EK102600 EK2000 AD600 2600 16...

Page 3: ...marked and scaled drawing your supplier will calculate the appropriate kit required 2 Floor preparation Cable kits can be laid onto most existing floor surfaces that are sound and suitably prepared A...

Page 4: ...quired and the electrical supply position form a channel in the floor adjacent to this point as illustrated THERMOSTAT SUPPLIED 45mm RECESSE D MOUNTING BOX REQUIRED FOR FLUSH MOUNTING 230VOLT SUPPLY F...

Page 5: ...t again If you have ordered the wrong size of kit contact your supplier Now and referring to the tables on page 1 test the cable circuit for continuity resistance using an ohmeter Avoid traffic over t...

Page 6: ...6 Flexel Installation Manual Cable Kit Instructions Finished Floor Diagrams Cross Section Flexible adhesive Tile finished with flexible grout...

Page 7: ...att cable 5 9m2 coverage Lay the additional cable and if necessary adjust the spacing to achieve full floor coverage The thermostat sensor must be positioned centrally between cable loops Tiling the f...

Page 8: ...440 multicoat for wet areas Mira 4800 antifire fluid primer Mira X Plan self Levelling acrylic and Fibre reinforced levelling compound Mira 3250 superplan Fix acrylic reinforced cement based quick cur...

Page 9: ...tching on Before switching on the underfloor heating allow a minimum of 3 days for natural drying of the tile adhesive and grout Initially operate the system for 2 3 hours per day increasing to full c...

Reviews: