SA
-FOM4 Installation Description
SA
-FOM4-2.0-20030102
5.2 CID Main Menu
E1 Unbalance 75 Ohm
1. Set In_Service (IS) Channel No. (1-4)
2. Set Out_Of_Service (OOS) Channel No. (1-4)
3. Set E1 Local Loopback (E1LLB) Channel No. (1-4)
4. Cancel E1 Local Loopback (E1LLB) Channel No. (1-4)
5. Set Near End (NE) Local Loopback (NELLB)
6. Cancel Near End (NE) Local Loopback (NELLB)
7. Set E1 Remote Loopback (E1RLB) Channel No. (1-4)
8. Cancel E1 Remote Loopback (E1RLB) Channel No. (1-4)
0. Report status
Please enter a selection [0-9]:
The “
E1 Unbalance 75 Ohm
” shows on the top right corner
indicates whether the equipment is set to 75 Ohm or 120
Ohm (for impedance setting please refer to Unit 5 System
Connections of this manual).
Please enter a selection [0-9]:
Selection
1
and
2
set E1 Service to In Service and Out Of
Service Status.
Selection
3
and
4
set and cancel E1 Local Loopback.
Selection
5
and
6
set and cancel Near End Local Loopback.
Selection
7
and
8
set and cancel E1 Remote Loopback.
-10-