background image

 

NOTE!

 

Components of the heater -

 

in particular outer 

 

covers -

 

are hot during operation. Appropriate 

 

caution is advised!

 

NOTE!

 

Never stand straight before the boiler when 

 

opening doors. Risk

 

of burns!

 

NOTE!

 

The grid chamber should always be closed, 

 

save for a start-up period, for loading and the 

 

removal of grid contaminants. 

7.3. Periodic heater maintenance -

 

cleaning and 

upkeep 

 

HINT!

 

In order to maintain appropriate combustion 

 

efficiency, keep the convection ducts and 

 

sheet metal inside the grid chamber 

 

appropriately clean. Soot, dust and ash from 

 

combustion shall reduce effectiveness and 

 

capacity of the combustion process. 

 

NOTE!

 

The operating temperature of the individual 

 

heater un

its can reach up to 600 °C.

 

 

In order to clean the heater,

 

shut it down and 

 

wait out the time necessary for the heat 

 

exchanger to cool down. 

 

NOTE!

 

Before commencement of maintenance 

 

procedures, disconnect the heater power 

 

supply!

 

NOTE!

 

All activities

 

need to be carried out with 

 

particular care. They can only be executed by 

 

adults. Ensure for children to stay clear and 

 

away from the heater during its cleaning 

 

procedure. Use

 

gloves, safety goggles and 

 

head protection when servicing the heater. 

 

 

 

 

 

 

 
 

 

 

In the grid chamber of the heater, pay particular 
attention to the precise removal of ash and slag 
from the grid grooves and chamber walls. Such 
cleaning should be carried out each time the 
heater is started up. Before cleaning, shut off the 
heater with its main switch, and wait out the 
period necessary for the heat exchanger to cool 
down. 

The exhaust ducts, in which volatile ashes 
gather, should be carried out through the 
inspection openings every seven to fourteen 
days, depending on the fuel quality and humidity.

Summary of Contents for FHSPN 35

Page 1: ......

Page 2: ...to the outside environment without any intermediate liquid During combustion smoke and other gases are generated which are ventilated by the chimney line NOTE Due to the specifics of operation of the...

Page 3: ...at 30 according to the standards indicated above 5 Heater technical data Rated power 35 kW 70 kW Power supply 230 V 50 Hz 400 V 50 Hz Energy consumption 1 2 A 1 6 A Fan air flow 5500 m3 h 12500 m3 h W...

Page 4: ...rmation of carbon monoxide a safe distance of at least 1 5 metres five feet be maintained from combustible materials during installation and operation of the heater FHSPN series heaters may be stored...

Page 5: ...d appropriate for the type of work being executed according to the work methods and the physical effort required to carry it out however not being lower than 14 C In working rooms in turn in which lig...

Page 6: ...NOTE All electric system connections are to be made by an electrician with the appropriate permits NOTE The user is forbidden from any interference or making any changes to the electric connections 6...

Page 7: ...of the unit note data in the warranty card HINT The conclusion of installation and the execution of a heating trial need to be noted in the warranty card The completed warranty card should be sent by...

Page 8: ...down and wait out the time necessary for the heat exchanger to cool down NOTE Before commencement of maintenance procedures disconnect the heater power supply NOTE All activities need to be carried ou...