R O O M I E W I F I
Operation of the ventilation unit with the buttons on the indoor unit
Speed
OFF
7KHVSHHGVHOHFWLRQVHTXHQFHLVDVIROORZVORZPHGLXPKLJK2))
All the units integrated in a single network operate according to the speed settings of the Master unit.
I
: permanent glowing of the lamp indicator indicates operation of the unit with low speed.
Blinking of the lamp indicates activation of the Night mode timer.
I
and
II
: permanent glowing of the lamp indicators
I
and
II
indicates operation of the unit with medium speed.
I
,
II
and
III
: permanent glowing of the lamp indicators I, II and III indicates operation of the ventilation unit with high speed.
Blinking of the lamp indicators
I
,
II
and
III
LQGLFDWHVDFWLYDWLRQRIWKHWLPHUIRU3DUW\PRGHRUWKHWXUQRGHOD\WLPHU
triggered by any connected external sensors or the integrated humidity sensor.
Alternate blinking of the lamp indicators
I, II
and
III
indicates operation of the ventilation unit at a set speed according to the
settings of the connected mobile device.
Regeneration mode
Roomie One WiFi
The fan rotation direction changes every 70 seconds.
Roomie Dual WiFi
The fans rotation direction changes to opposite every 70 seconds.
Ventilation mode.
Roomie One WiFi
The ventilation unit operates in the supply or extract mode at set speed. The fan rotation direction depends on PC setting
(extract mode by default).
Roomie Dual WiFi
One of the fans of the ventilation unit operates in the extract mode and the other one operates in the supply mode at set
VSHHG7KHDLUȵRZGLUHFWLRQPDLQVFRQVWDQW
No glowing of the indicator lamps «Regeneration» and «Ventilation» indicates forced operation of the ventilation unit in the supply mode. This mode
may be activated only via the mobile application.
Filter
)LOWHUUHSODFHPHQWLQGLFDWRUGD\VDIWHULQVWDOODWLRQRIWKHFDUWULGJHWKHȴOWHUUHSODFHPHQWLQGLFDWRUVWDUWVJORZLQJΖQWKLVFDVH
UHSODFHRUFOHDQWKHȴOWHUVDVGHVFULEHGLQ0DLQWHQDQFHVHFWLRQ$IWHUUHSODFHPHQWRIWKHȴOWHUVUHVHWWKHWLPHUXVLQJWKH'Ζ3
switch.
Alarm
Alarm indicator for emergency shutdown of the unit. Permanent glowing of the Alarm indicator of the Master unit indicates
DQDODUPLQWKHQHWZRUNRIWKHFRQQHFWHGYHQWLODWLRQXQLWVΖWVEOLQNLQJLQGLFDWHVVKXWGRZQRIDVSHFLȴFYHQWLODWLRQXQLWLQWKH
network. In case of an emergency shutdownof a Roomie One WiFi unit in the network the defective ventilation unit is marked
with the blinking Alarm indicator. All the connected Roomie One WiFi units are also stopped. In case of an emergency shutdown
of a Roomie Dual WiFi unit in the network the defective ventilation unit is marked with the blinking Alarm indicator.The defective
ventilation unit shuts down and the other connected ventilation units continue their operation.
Master
Permanent glowing of the lamp indicator indicates the leading unit in the network (Master unit). Blinking of the indicator indi-
cates the driven unit (Slave) and no connection to the Master unit. No glowing of the lamp indicator means that this ventilation
unit is a Slave ventilation unit and it is connected to the Master unit.
Synchronous blinking of all the lamp indicators on the casing of the ventilation unit means activated setup mode performed by a PC.
In this case the fan shuts down.
Remote control of the ventilation unit
7XUQLQJWKHXQLWRQR
7KHXQLWPD\EHWXUQHGRRQO\LILWLVHQDEOHGE\WKHVHWWLQJV
Reset of alarm and timer settings.
Speed selection: high-medium-low respectively.
Regeneration mode.
Roomie One WiFi
The fan rotation direction changes every 70 seconds.
Roomie Dual WiFi
The fans rotation direction changes to opposite every 70 seconds.
Ventilation mode.
Roomie One WiFi
The ventilation unit operates in the supply or extract mode at set speed. The fan rotation direction depends on PC setting
(extract mode by default).
Roomie Dual WiFi
One of the fans of the ventilation unit operates in exhaust mode and the other one operates in the supply mode at set speed.
7KHDLUȵRZGLUHFWLRQPDLQVFRQVWDQW
Timer control button:
Party mode: the timer activates operation of the unit at high speed for a set time period, 4 hours by default. The setting
may be edited during setup of the unit or using the mobile application.
Night mode: the timer activates operation of the ventilation unit at low speed for a set time period, 8 hours by default. The
timer setting may be changed during setup of the unit or using the mobile application.
The ventilation unit reverts to operation with a previous speed setting upon elapse of the set time period.
Press any speed setting key to deactivate the timer or press the timer control button once again.