22
R O O M I E W I F I
5HVHWȴOWHUWLPHU
• Select the tab
Filter
.
• Press the button
5HVHWȴOWHUWLPHU
to reset
WKHȴOWHUWLPHU$IWHUUHSODFHPHQWRIWKHȴOWHUVWKH
operating hours are displayed above the button (2).
Emergency shutdown of the unit
Emergency shutdown of the unit appears if the fan shut-
down lasts above 5 seconds.
In case of emergency shutdown of any
Roomie One WiFi
unit in a chain all the
Roomie One WiFi
units stop. The
Roomie Dual WiFi
units continue to operate.
In case of emergency shutdown of any
Roomie Dual
WiFi
unit all the other units in the chain continue to
operate.
1
2
3
$ODUPLVFRQȴUPHGE\DUHVSHFWLYHDODUPLQGLFDWLRQIRU
all the ventilation units in the network, see page 134.
To reset the alarm indication troubleshoot the fan shut-
down and restart the unit using the button on the indoor
unit or the remote control.
If the alarm indication is still active, please refer to the
Seller.
&XWRSRZHUVXSSO\WRDGHIHFWLYHXQLWWRHQDEOH
operation of the other units in the network.
• Humidity control scenario (for Roomie Dual WiFi):
setting reaction of the ventilation unit for activation of any
sensor or the built-in humidity sensor. When choosing
exhaust mode both fans extracts air.
•
7XUQRGHOD\WLPHU
setting reset time to a previous
operation mode for the ventilation unit after activation of
any connected sensors or the built-in humidity sensor.
• Night mode timer:
setting reset time to a previous
operation mode after activation of the night mode,
factory setting 8 hours.
• Party mode timer:
setting changeover time for high-
speed mode after activation of the Party mode, factory
setting 4 hours.
• Humidity sensor:
activation of the humidity sensor. When
the indoor humidity exceeds the set point (12), the unit
changes to the high speed. When the indoor humidity
GURSVGRZQEHORZWKHVHWSRLQWWKHWXUQRWLPHUVVWDUWV
countdown and then the unit changes to the previous
speed.
• Relay sensor:
activation of the external relay sensor.
When the no-contact of the external relay sensor is
closed, the unit changes to the high speed exhaust mode.
:KHQWKHQRFRQWDFWLVRSHQWKHWXUQRWLPHUVVWDUWV
countdown and then the unit changes to the previous
speed.
• 0-10V sensor:
activation of the external analogue sensor
0-10V. When a 0-10V control signal value exceed the
set point (13), the ventilation unit changes to the high
speed exhaust mode. As the control signal value falls
GRZQEHORZWKHVHWSRLQWWKHWXUQRWLPHUVWDUWVLWV
countdown and upon its elapsing the unit reverts to
operation with the previous speed.
• Apply:
application of all the set parameters in the tab.