7 June 2021(FW:0.9.12, Utility: 0.9.12)
7.4 Transmitting
When
transmitting,
the
PTT
indicator
is
illuminated,
and
the
front
panel
display
looks
like
the
following:
The
elements
of
the
display
are
detailed
in
the
following
sections.
7.4.1 Power Meter (PWR)
The
power
meter
indicates
the
transmitted
peak
and
average
power.
It
ranges
from
0
to
2000
watts.
In
addition,
a
maximum
power
indicator
is
shown
when
demanded
by
the
limits
of
the
tuning
solution.
i
–
Power
measurements
update
approximately
every
100ms
and
should
be
used
for
reference
only.
For
a
more
accurate
power
reading,
transmit
a
fixed
amplitude
and
frequency
signal
for
at
least
1
second.
7.4.2 SWR meter
The
SWR
meter
shows
the
Standing
Wave
Ratio
(SWR)
on
the
input
port
after
the
tuning
solution.
It
represents
the
SWR
"seen"
by
the
transmitter
or