background image

FLEXTOOL OPERATING INSTRUCTIONS

POWERVIBE HIGH FREQUENCY VIBRATOR

4

1300 353 986  

flextool.com.au

Model 

Operating 

Weight 

(kg)

Vibrator 

Head 

Diameter

(mm)

Vibrator 

Head 

Length

(mm)

Flexshaft 

Length

(m)

Amplitude

(mm)

Centrifugal 

Force (kN)

Vibration 

(vpm)

Voltage 

(v)

Current 

(A)

Power 

Cable 

Length 

(m)

Shipping 

Dimensions

(L x W x H)

(mm)

Shipping 

Weight

(kg)

Product 

Code

FPV-45

17.7

45

368

6

2

2.6

12000

240

6

10

890 x 730 

x 120

19.7

FT201831-

UNIT

FLEXTOOL

®

 POWERVIBE

™ 

HIGH FREQUENCY CONCRETE VIBE 45MM (FPV-45)

Model 

Operating 

Weight 

(kg)

Vibrator 

Head 

Diameter

(mm)

Vibrator 

Head 

Length

(mm)

Flexshaft 

Length

(m)

Amplitude

(mm)

Centrifugal 

Force (kN)

Vibration 

(vpm)

Voltage 

(v)

Current 

(A)

Power 

Cable 

Length 

(m)

Shipping 

Dimensions

(L x W x H)

(mm)

Shipping 

Weight

(kg)

Product 

Code

FPV-60

20.5

60

436

6

2.2

4.5

12000

240

6

10

890 x 730  

x 120

22.5

FT201832-

UNIT

FLEXTOOL

®

 POWERVIBE

™ 

HIGH FREQUENCY CONCRETE VIBE 60MM (FPV-60)

Summary of Contents for POWERVIBE FPV-45

Page 1: ...010520 WARNING To reduce the risk of injury all operators and maintenance personnel must read and understand these instructions before operating changing accessories or performing maintenance on this power equipment All possible situations cannot be covered in these instructions However care must be exercised by everyone using maintaining or working near this equipment ...

Page 2: ...rior to connecting to the power socket ensure the PowerVibe control switch is in the OFF O position 2 Connect the PowerVibe to the power socket 3 Push the reset button on the RCD protection unit to active the device 4 Push the control switch to the ON I position to start the PowerVibe 5 Vibration will start after 2 seconds at low speed Vibration will then slowly increase to maximum operating speed...

Page 3: ...supplies of concrete to be placed Vibrator heads are designed to be cooled by the concrete in which they are immersed DO NOT drag the concrete vibrator through the concrete or use it shift or move the concrete Using a concrete vibrator in this way will cause damage to the vibrating head and flexshaft 1 Place the concrete vibrator head into the concrete so that the vibrating head is at ninety degre...

Page 4: ...roduct Code FPV 45 17 7 45 368 6 2 2 6 12000 240 6 10 890 x 730 x 120 19 7 FT201831 UNIT FLEXTOOL POWERVIBE HIGH FREQUENCY CONCRETE VIBE 45MM FPV 45 Model Operating Weight kg Vibrator Head Diameter mm Vibrator Head Length mm Flexshaft Length m Amplitude mm Centrifugal Force kN Vibration vpm Voltage v Current A Power Cable Length m Shipping Dimensions L x W x H mm Shipping Weight kg Product Code FP...

Reviews: