ELECTRIC  OPERATED,  PISTON COMPRESSORS

 

Flexzilla

  designs and manufactures products for safe opera on. However, operators and maintenance persons are 

responsibile for maintaining safety. All safety precau ons are included to provide a guideline for minimizing the 

possibility  of  accidents  and  property  damage  while  equipment  is  in  opera on. 

Keep  these  instru ons  for  reference.

 

 

 

1811

Operating Instructions &
Warranty Registration

 

TO ACTIVATE

WARRANTY

Scan or go to 

for warranty registration

Warranty only valid by following conditions expressed in the Warranty Statement section of the Compressor Operating Manual.

Summary of Contents for FI05V080Y1S

Page 1: ...are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in opera on Keep these instru ons for reference 1811 Operating Instructions Warr...

Page 2: ...30 460 575 APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T 640 640 800 800 800 800 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 735 735 752 752 1190 1190 956 956 988 956 1200 1200...

Page 3: ...xcept in full compliance with OSHA Standards 29 CFR 1910 and any other Federal State or Local codes or regula ons Death or serious injury can result from inhaling compressed air without using proper s...

Page 4: ...n a temperature range between 35 110 F Ifambienttemperaturedrops below 32 F be sure to protect safety relief valves and drain valves from freezing NEVER operate compressor with temperatures below 15 F...

Page 5: ...top to minimize condensa on in air drop ELEVATION Watertrap with drain Air Tank Air Dryer From Compressor To Air Tool Water Drain Valve Figure 2 Basic Piping Diagram Never install a shut o valve such...

Page 6: ...circuit can cause circuit overload and or imbalance in motor phasing Install proper No Fuse Breaker NFB according to kW output of compressor 3 Ensure incoming service has adequate ampere ra ng 4 Ensu...

Page 7: ...220V or 460V Opera on SafetyRules 1 Make sure all operators receive product train ing and read and understand all instruc ons Keep all ammable combus ble poisonous and noxious materials away from oper...

Page 8: ...liminate numerous motor starts stops and to help coolpump To engage con nuous run feature open ball valve found by following copper tubing across cylinder heads to tank See gure 9 Stop con nuous run f...

Page 9: ...comes milky Safety Valve NEVER a empt to regulate or tamper with safety valve Valve is sealed and cer ed by ASME code and is designed to relieve system pressurewhennecessary Check proper opera on of s...

Page 10: ...clockwiserota on 3 Clean or replace 4 Replace gasket s 5 Clear blockage 6 Add oil Ensure oil level is at middle of site glass See gure 8 Use only Flexzilla Compressor Oil Use of any other product will...

Page 11: ...r unit If the unit runs out of oil this warranty is void Failure to fully comply with this warranty and fully comply with the manual herein will also void this warranty WEEMS GLOBAL WARRANTY EXCLUSION...