background image

Flexzilla 

Electric Operated, Piston Compressors

 

7

 

Breaker

Power Supply

220 V 

Power Power

Common

 

Wire connec on 

from coil  to 

pressure switch

 

Breaker

Power Supply

220 V 

Power Power Power

Common

 

Wire connec on 

from coil  to 

pressure switch

 

ground wire

 

3

ground wire

 

A1

A2

Pressure

Switch

A1

A2

Pressure

Switch

1L1    3L2   5L3

1L1    3L2   5L3

110V Power 

Wires

 

Jumper wire 

from 3L2  power 

to NC96

 

Jumper wire 

from 1L1 to

 

Mag

A2

Starter

T1     T2     T3

Jumper wire 

from bo om of 

selector  switch

 

to pressure  switch

 

110V Power 

Wires

 

Jumper wire 

from 3L2  power 

to NC96

 

Jumper wire 

from 1L1 to

 

Mag

A2

Starter

T1     T2     T3

Jumper wire 

from bo om of 

selector  switch

 

to pressure  switch

 

top of

 

NC  

Thermal 

NC

Jumper wire

 

fr

 

top of

 

NC  

Thermal 

NC

selector  switch

 

ON-OFF

 

Selector  Switch

 

(if equipped)

96

Overload

95

T1

T2

T3

om NC95 to  A2

 

Large jumper  wire 

5L3 to T2 on  overload

 

Motor

selector  switch

 

ON-OFF

 

Selector  Switch

 

(if equipped)

96

Overload

95

T1     T2    T3

Jumper wire 

from NC95 to  A2

 

Motor

Three Phase Motors 

(See 

gure 7)

 

1. Connect 

rst power lead to  1L1.

2. Connect second power lead to  3L2.
3. Connect third power lead to  5L3.
4. Connect  ground  wire  to  exis ng  motor  ground

wire.

5. Check for proper motor rota on. When facing

motor sha , pulley should turn counterclock- 

wise. If rota on is reversed, 

turn o

 power

then switch two power  leads.

Ensure wiring is installed 

according to voltage required for

 

proper motor opera on (220V or   460V).

 

Opera on

 

Safety Rules

 

1. Make sure all operators receive product train- 

ing and read and understand all

 

instruc ons.

Keep all 

ammable, combus ble, 

poisonous and noxious  materials 

away from opera ng area. Make 

sure there are no oily rags, trash, 

leaves, li er or other combus ble 

materials in opera ng area.  Keep

 

suitable, fully charged 

re ex nguishers nearby 

when servicing and opera ng the compressor.

 

2.

NEVER 

allow modi

ca ns to compressor

structure or controls.

3. Keep all igni n sources away from exposed

electrical parts.

4. Keep all persons clear of compressor during

start-up and  opera on.

5. NEVER  operate  the  compressor  with  the  fan,

coupling or other guards removed.

6. DO NOT engage in horseplay with air hoses as

death or serious injury may result.

7. Make sure to provide adequate  ven la on 

and use proper lubricant while opera ng the

compressor. If lubricant or other  combus ble

substances are spilled, clean up immediately.

8. When checking or adding lubricant or when re- 

fill

ing air line an -icer systems with an freeze

compound, shut o

 compressor and allow it to

cool. Keep sparks, 

ames and other  igni on

sources away and DO NOT permit smoking in the

vicinity.

9. Stop compressor and disconnect power if a

hazardous condi on  arises.

10. Wear snug 

ng clothing and con

ne long hair

when around compressor. Keep all body parts

and clothing away from couplings, 

ywheel  and

other moving parts of the equipment.

 

TO ACTIVATE

WARRANTY

Scan or go to 

for warranty registration

Warranty only valid by following conditions expressed in the Warranty Statement section of the Compressor Operating Manual.

Summary of Contents for FI05V080Y1S

Page 1: ...are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in opera on Keep these instru ons for reference 1811 Operating Instructions Warr...

Page 2: ...30 460 575 APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T APP4V1043T 640 640 800 800 800 800 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT 3 4 735 735 752 752 1190 1190 956 956 988 956 1200 1200...

Page 3: ...xcept in full compliance with OSHA Standards 29 CFR 1910 and any other Federal State or Local codes or regula ons Death or serious injury can result from inhaling compressed air without using proper s...

Page 4: ...n a temperature range between 35 110 F Ifambienttemperaturedrops below 32 F be sure to protect safety relief valves and drain valves from freezing NEVER operate compressor with temperatures below 15 F...

Page 5: ...top to minimize condensa on in air drop ELEVATION Watertrap with drain Air Tank Air Dryer From Compressor To Air Tool Water Drain Valve Figure 2 Basic Piping Diagram Never install a shut o valve such...

Page 6: ...circuit can cause circuit overload and or imbalance in motor phasing Install proper No Fuse Breaker NFB according to kW output of compressor 3 Ensure incoming service has adequate ampere ra ng 4 Ensu...

Page 7: ...220V or 460V Opera on SafetyRules 1 Make sure all operators receive product train ing and read and understand all instruc ons Keep all ammable combus ble poisonous and noxious materials away from oper...

Page 8: ...liminate numerous motor starts stops and to help coolpump To engage con nuous run feature open ball valve found by following copper tubing across cylinder heads to tank See gure 9 Stop con nuous run f...

Page 9: ...comes milky Safety Valve NEVER a empt to regulate or tamper with safety valve Valve is sealed and cer ed by ASME code and is designed to relieve system pressurewhennecessary Check proper opera on of s...

Page 10: ...clockwiserota on 3 Clean or replace 4 Replace gasket s 5 Clear blockage 6 Add oil Ensure oil level is at middle of site glass See gure 8 Use only Flexzilla Compressor Oil Use of any other product will...

Page 11: ...r unit If the unit runs out of oil this warranty is void Failure to fully comply with this warranty and fully comply with the manual herein will also void this warranty WEEMS GLOBAL WARRANTY EXCLUSION...

Reviews: