Warranty Statement Piston Air Compressors

WEEMS GLOBAL® (and each of its subsidiaries) makes the following warran�es:

Standard Warranty:

 That each compressor unit is free from defects in material, workmanship, and parts for 1 year from the 

date of delivery. This Standard Warranty includes 1 year of warranty labor from an authorized technician. Eaton compressor 

is not responsible for down�me during warranty service. If down�me is necessary, it is at the owner’s discre�on, obliga�on, 

and expense, to have a redundant compressor. Parts shipped for warranty repairs shall only include ground freight charges 

for the first 6 months of the warranty period, therea�er owner is responsible for all freight charges of parts shipped for 

warranty. Any and all express shipping charges of warranty parts would be at the owner’s expense. Standard technical 

assistance is provided at no charge during and a�er the standard warranty period.

*Standard warranty has no obligation to maintain warranty status, warranty will expire one year from date of delivery. 

Please see available options below to extend your warranty.

Extended Warranty: 

WEEMS GLOBAL will extend your standard 1-year warranty to full 5 years when you opt to register 

for the extended warranty plan that includes using our SMART OIL™ and following all rou�ne maintenance set forth. 

Parts shipped for warranty repairs shall only include ground freight charges for the first 6 months of the warranty period, 

therea�er owner is responsible for all freight charges of parts shipped for warranty. Any and all express shipping charges 

of warranty parts would be at the owner’s expense. Standard technical assistance is provided at no charge during and 

a�er the standard warranty period.

Required maintenance Schedule to maintain warranty status:

• All units are shipped with break-in oil and must be changed no less than 150 hours to insure gasket sea�ng

• A�er the 150 hours of break-in you must change the oil

• Therea�er oil should be changed every 6 months or 1000 hours whichever occurs first

• Always maintain proper oil level in unit. If the unit runs out of oil due to neglect the warranty will be void

• Use only Flexzilla approved oils in your compressor, or your warranty is void

**Extended Limited Lifetime Pump Warranty:

 

With par�cipa�on in our SMART OIL™ extended auto ship program 

WEEMS GLOBAL will extend your warranty plan to **Limited Life�me Warranty on the pressure lubricated pump. All 

other non-wear and tear components to 10 years. SMART OIL™ not only extends the life of your compressor pump, it 

also can reduce opera�ng noise levels and can create further energy savings. Warranty repair parts under the Limited 

Life�me warranty will not include any shipping charges beyond the Standard Warranty, therefore owner is responsible 

for all freight charges for warranty parts. This plan includes our advanced technical air support. Smart Tech Support 

provides you with the highest level of technical support. Smart Tech support is an interac�ve support team available to 

you at your finger�ps by just downloading a free app. The app provides free remote mee�ngs, interac�ve touch display, 

real live personnel to assist.

Limited Life�me Warranty is not prorated and has no hour limits.

**Limited Life�me Warranty, non-prorated, no hour limits. In the case the product has been discon�nued at any point the 

Limited life�me Pump warranty will last five years past the discon�nued date. Warrantor has discre�on to subs�tute parts 

with current model for the five-year dura�on

*In order to maintain Limited Lifetime Warranty status, the owner must adhere to and purchase from Eaton Compressor the 

required maintenance items as scheduled below utilizing our Smart Whisper Blue Auto Ship program.

Required maintenance Schedule to maintain warranty status:

• All units are shipped with break-in oil and must be changed no less than 150 hours to insure gasket sea�ng

• A�er the 150 hours of break-in you must change the oil

• Therea�er oil should be changed every 6 months or 1000 hours whichever occurs first using only our Smart 

   Whisper Blue Oil

• Always maintain proper oil level in unit. If the unit runs out of oil due to neglect the warranty will be void

• Use only Smart Whisper Blue Oil and filters purchased from Eaton Compressor in your compressor, or your warranty will 

   be  voided

• Must be an ac�ve member of Eaton Compressor auto ship program

Summary of Contents for FXS07V080V1

Page 1: ...anty Manual Published 2018 05 14 Revised 2022 11 08 responsible IMPORTANT MUST READ NEED TO CONFIRM WHETHER YOUR ELECTRICAL SYSTEM IS 1 PHASE OR 3 PHASE IF 3 PHASE MUST CONFIRM VOLTAGE FOR 3 PHASE COM...

Page 2: ...ase 39 175 10 HP 1750 208V 230V APP4V1043T 800 NPT 3 4 1020 1200 34 2 Contents Warranty Activation 2 Model Specification Charts 2 Description 2 Safety Information 3 Tag Definitions 3 Basic Guidelines...

Page 3: ...ons Death or serious injury can result from inhaling compressed air without using proper safety equipment See OSHA standards on safety equipment 2 DO NOT use air line an icer systems in air lines sup...

Page 4: ...t safety relief valves and drain valves from freezing NEVER operate compressor with temperatures below 15 5 2 1 e v o b a r o F F 2 Allow su cient space around compressor for maintenance access and ad...

Page 5: ...er From Compressor To Air Tool Water Drain Valve Figure 2 Basic Piping Diagram Never install a shut o valve such as a glove or gate valve between the pump discharge and the air tank unless a safety va...

Page 6: ...eaker NFB according to kW output of compressor 3 Ensure incoming service has adequate ampere ra ng 4 Ensure supply line has the same electrical char acteris cs voltage cycles and phase as the electric...

Page 7: ...d n a t s r e d n u d n a d a e r d n a g n i ons Keep all ammable combus ble poisonous and noxious materials away from opera ng area Make sure there are no oily rags trash leaves li er or other combu...

Page 8: ...un feature open ball valve found by following copper tubing across cylinder heads to tank See gure 9 Stop con nuous run feature by closing valve so com h c t i w s e r u s s e r p o t g n i d r o c c...

Page 9: ...12 1 bar DO NOT a empt mately 1 2 inch of de ec on 1 2 De ec on e r u s s e r p r e d n u s i e n i h c a m e l i h w e v l a v n e p o o t Tank 2 Adjust belt tension as needed by loosening the four...

Page 10: ...pressor 8 Increase ven la on around opera ng area Ensure compressor has adequate clear space from walls and other possible obstruc ons Ambien emperature should not exceed 11 F Check for proper oil lev...

Page 11: ...s rst Always maintain proper oil level in unit If the unit runs out of oil due to neglect the warranty will be void Use only Flexzilla approved oils in your compressor or your warranty is void Extende...

Page 12: ...dule Warranty shall be voided under the following condi ons Exposing electrical components to rain or water or installing the unit in a hos le environment such as acid vapors or any caus c or abrasive...