background image

 

 
117-00008 Rev 3.0 Flightcell® DZMx Installation Manual 

Page 74 of 75 

Effective Date: 18 February 2022 

 

Appendix 1: Connector Kits & Associated Parts 

Connector kits provided with the DZMx 

 DESCRIPTION 

SUPPLIED WITH 

COMPONENT DESCRIPTION 

QTY/ KIT 

CNP_00003 - Flightcell 

Cradle D38999 

Connector Kit 

Flightcell Iridium 

Phone Cradles with 

military connectors 

CNC_00002 - TNC crimp plug, RG58 

CNC_00011 - D38999/26WD-35SN 

Straight plug 

CNC_00014 - M85049/38S-15A - 

D38999 Strain Relief Cradles 

CNP_00004 - Flightcell 

Cradle D25 Connector 

Kit 

Flightcell Iridium 

Phone Cradles with 

civilian connectors 

CNC_00002 - TNC crimp plug, RG58 

CNC_00004 - DB25S M24308 Crimp 
and Poke Socket with Contacts 

(Female) 

CNC_00026 - Metal Back Shell for DB 

Size connectors Straight (25 way) 

CNP_00005 - Dual 
Antenna BNC/TNC 

Connector Kit 

Dual Iridium/GPS 
antennas 

CNC_00100 - BNC plug R/A 50 OHM 
Crimp 

CNC_00101 

 TNC plug R/A 50 OHM 

Crimp 

CNP_00029 - Single 
Antenna TNC 

Connector Kit 

Single Iridium 
antennas 

CNC_00101 

 TNC plug R/A 50 OHM 

Crimp 

CNP_00030 - Flightcell 

DZM Remote Head 
Connector Kit 
  

Flightcell DZMx 

Remote Head 
  

CNC_00046 - Metal Back shell for DA 

Size connectors Straight (15 way) 

CNC_00048 - DA15S M24308 Crimp 

and Poke Socket with Contacts 

(Female) 

CNP_00035 - Flightcell 

DZMx Civilian 

Connector Kit 

Flightcell DZMx - all 

versions with 

standard (D-25) 

connectors 

CNC_00004 - DB25S M24308 Crimp 

and Poke Socket with Contacts 

(Female) 

CNC_00050 - DB25P M24308 Crimp 

and Poke Plug with Contacts (Male) 

CNC_00026 - Metal Back Shell for DB 

Size connectors Straight (25 way) 

CNC_00002 - TNC crimp plug, RG58 

CNC_00001 - BNC crimp plug, RG58 

IDP_00013 - Flightcell USB/Ethernet 

Civilian Connector Box 

CNC_00023 - DE9S M24308 Crimp 

and Poke Socket with Contacts 

(Female) 

CNC_00027 - Metal Back shell for DE 

Size connectors Straight (9 way or 15 

way HD) 

 
 

 

Summary of Contents for DZMx

Page 1: ...117 00008 Rev 3 0 Flightcell DZMx Installation Manual Effective Date 18 February 2022 DZMx Installation Manual Product Revision 6 1 Firmware Version 3 8 1 and 4 8 1 ...

Page 2: ...uctions for configuration of DZMx data and activation of firewall between ethernet and Wi Fi networks Updated details for management of cellular data connections DZMx Firmware Release 4 8 1 for DZP_04 Rev 4 0 5 0 6 0 and 6 1 and Firmware Release 3 8 1 for DZP_04 Rev 3 0 Except as expressly provided below no part of this document may be reproduced copied transmitted disseminated downloaded or store...

Page 3: ...TION 19 Accessing Installation and Configuration Settings 19 Configuring the DZMx 19 Audio Installation and Configuration 22 Modem Configuration 26 Configuring the cellular bands used by the DZMx cellular modem 30 Backlighting 32 DZMxData 38 DZMx WiFi 40 DZMx Bluetooth 41 DZMx Messaging 44 DZMx Tracking 44 DZMx Inputs and Outputs 54 DZMx Data Logging 57 DZMx Email Outbox 58 Recording and Transmitt...

Page 4: ...nfiguration of the DZP_04 Flightcell DZMx Previous revisions of this manual have the document number MAN_DZ4_001 and are still available on request Applicability of this Manual This manual applies to DZP_04 Flightcell DZMx revisions 3 0 4 0 5 0 6 0 and 6 1 DZP_04 Rev 6 1 operating firmware 4 8 1 Rev 4 0 5 0 and 6 0 upgraded to firmware 4 8 1 Rev 3 0 upgraded to firmware 3 8 1 ...

Page 5: ...Connector Module It is compulsory that DZMx USB and Ethernet connections are installed on the aircraft If the USB Ethernet connections are not installed into the aircraft it will severely limit troubleshooting and support capabilities A Flightcell USB Ethernet connector module is provided with each DZMx to provide a convenient option for terminating the DZMx USB and Ethernet connections It is acce...

Page 6: ...tes the variant of the DZMx The available variants may change from time to time The options available to build up the different variants are Installed modems Faceplate options DZUS 5 mount GA 6 mount Type of main connector Standard two D25 connectors Military one mil spec D38999 connector NVIS compliance NVIS B NVIS A Mil Std 3009 only available on versions with military connectors Embedded Wi Fi ...

Page 7: ... 28VDC ICS to DZMx Input Levels VRMS 20mV to 1 15V adjustable 775mV nominal Input Impedance 600Ω Microphone Bias Voltage 12V via 2 2kΩ Output Levels VRMS Up to 5V adjustable DZMx to ICS 775mV nominal Output Impedance 150Ω Backlighting Input Control 0 to 28VDC User calibrated High Low set points Colour Green 520nm Designed for NVIS B compliance GPS Antenna Bias Voltage 5V Antenna Current Up to 100m...

Page 8: ...l power dBm 12 6 Total power mW 18 2 Environmental Qualifications The DZMx is tested against and complies with RTCA DO160G Details of the DO160G compliance are provided in the DZMx Declaration of Design and Performance DDP document TEC_DZ4_031 Issue 7 for DZMx Revision 3 and Issue 8 for DZMx Revision 4 0 document 122 00001 Issue 1 0 for Revision 5 0 Issue 1 1 for Revision 6 0 and Issue 1 2 for Rev...

Page 9: ... www flightcell com resources DZUS GA Mech Assembly for versions with DZUS front plate and D25 main connectors GA GA Mech Assembly for versions with GA front plate and D25 main connectors DZUS Mil Mech Assembly for military versions with DZUS front plate and D38999 main connectors CAD solid model files are also available on request from Flightcell International Contact tech flightcell com for more...

Page 10: ... as they provide the following functions Ethernet provides a connected device access to the DZMx data connections and to DZMx Connect USB required for firmware upgrades and downloading diagnostics The cable run to the USB connector should be limited to 5m of proper USB Cable to ensure compliance with the USB 2 0 cable delay specification An alternative USB or Ethernet socket may be used if preferr...

Page 11: ...ces RS232 available for serial data connections to some external devices and as a debug port RS422 RS485 used for serial data connections and connection to one or more DZMx Remote Heads Two additional data connections are available by installation of optional expansion cards in the DZMx ARINC 429 used to send and receive over the aircraft ARINC 429 data bus Second Ethernet used to provide a second...

Page 12: ...configurable 10 MIC TO DZMx 2 HI Input Unbiased biased configurable 11 POTS TIP I O For optional telephone handset 12 AUX DATA TX Input 13 AUX DATA Rx Output 14 CHASSIS GND Ground Internally connected to DZMx Chassis 15 GENERAL PURPOSE INPUT 5 Input Lighting dimmer input optional 16 GENERAL PURPOSE INPUT 1 Input 17 GND Ground 18 GENERAL PURPOSE INPUT 4 Input 19 RS485 Tx Output 20 RS485 Rx Input 21...

Page 13: ...pabilities 7 USB VBUS Power 8 USB D I O 9 USB D I O 10 GPIO5 Output Reserved for Optional Capabilities 11 GPIO6 Output Reserved for Optional Capabilities 12 ETH 10 100 TX Output 13 ETH 10 100 TX Output 14 AUDIO TO AUX TXCVR HI Output 15 AUDIO TO AUX TXCVR LO Output 16 AUDIO FROM DZM2 LO Output LO audio output to ICS 2 17 OUTPUT 1B Output Isolated output 1 Terminal B 18 OUTPUT 2B Output Isolated ou...

Page 14: ... Military Connector Connector type D38999 24WE 35PN Mating part D38999 26WE 35SN or equivalent Pin No Function Direction Notes 1 ETH 10 100 TX Output 2 ETH 10 100 RX Input 3 ETH 10 100 RX Input 4 AUDIO FROM DZMx 2 LO Output LO audio output to ICS 2 5 ETH 10 100 TX Output 6 SHIELD Shield Spare Shield Connection 7 SHIELD Shield Spare Shield Connection 8 CHASSIS GND Ground 9 GPIO5 Output Reserved for...

Page 15: ... Output Isolated output 2 Terminal A 24 GPIO7 I O Reserved for Optional Capabilities 25 DC SUPPLY VOLTAGE Input DC power supply 26 MIC TO DZMx 2 HI Input HI audio input from ICS 2 27 LO audio input from ICS 2 28 RS485 TX Output 29 RS485 TX Output 30 GPIO1 Input Reserved for Optional Capabilities 31 USB D I O 32 POTS RING I O For optional cabin phone 33 AUDIO FROM AUX TXCVR LO Input 34 MIC TO DZMx ...

Page 16: ...a connections The Remote Head also requires a 12 32VDC power supply Two additional connections are a ground connection to the chassis and a lighting input for external lighting control Backlighting of the DZMx and Remote Heads can be configured individually see page 32 for details on adjusting the brightness and the installing the external lighting input A wiring diagram of the Remote Head is incl...

Page 17: ...sible The following should be considered when determining a mounting location Maintain good separation from other antennas Preferred separation is 750mm from L band GPS TCAS or transponder antennas but a lesser separation can be applied if there is limited space on the aircraft On a helicopter the antenna can be installed below the rotor blades but avoid installing it close to the rotor hub as the...

Page 18: ...200 or RG142A U 9006 cellfoil Up to 8m RG213 Up to 17m LMR400 Up to 26m LMR600 It is recommended that the antenna cable be reduced to RG58 for the last 300mm to the DZMx to assist with installation in the panel Antenna connectors on the DZMx and Flightcell antennas as well as the supplied mating connectors are colour coded to reduce installation errors as follows Antenna Type Colour as seen in the...

Page 19: ...x keypad and display or using DZMx Connect Most settings are available on both interfaces It is recommended that DZMx Connect is used to configure and to change settings as it is faster and provides a more intuitive interface than the DZMx keypad However it is useful to use the DZMx keypad when real time feedback on the configuration is preferred Adjusting audio settings Configuring the general pu...

Page 20: ...Android application available from the respective app stores or as a browser application on a PC There are three ways to use DZMx Connect Hardwired Computer Connection Connect a computer to the DZMx Ethernet port Power up the DZMx and wait for it to fully initialise Open a web browser type 192 168 4 1 in the address bar and press ENTER The home screen of DZMx Connect will open in the browser If th...

Page 21: ...the address in the Stored Devices list Click on the discovered DZMx unit to open navigation and settings options To watch a short video explaining DZMx Connect capabilities Click here demonstrated on the app version Permission levels Permission levels allow control over how the DZMx is configured Three levels or roles with individually configurable passwords are available within DZMx Connect To ac...

Page 22: ... the ICS if possible Modem connections to the ICS are configured using DZMx Connect Go to Settings Audio Modems Single or Dual ICS Connections The DZMx supports one or two connections to the audio panel ICS ICS1 and ICS2 The dual ICS connections may be used to allow the DZMx to be connected to two different audio panels on the aircraft or to allow different audio connections to be used simultaneou...

Page 23: ...r to www flightcell com resources for wiring diagrams for the microphone connections Low Impedance Microphones When installing the DZMx with an ICS that uses low impedance mics the DZMx must be connected to a line level Radio Comms port If a line level port is not available and the DZMx is to be connected direct to the mic line then a tactical radio adaptor will be needed to match impedances Optio...

Page 24: ...t in some installations may not be available Side tone can be supplied by the DZMx if required This can be configured using the On the DZMx Control Head go to MENU Audio ICS Mic Bias On DZMx Connect go to Settings Audio ICS1 or ICS2 Select Off to disable side tone When on Call to enable only during a call or Always On to leave active all the time Configuring Notification Tones Notification tones a...

Page 25: ...acting orders flightcell com To enable and configure your DZMx for PTT using DZMx Connect go to Settings Modem Internal Sat modems If you wish to have the DZMx start up in PTT mode activate Start PTT on Boot If the PTT talkgroups are changed by your Iridium Service Provider it is recommended to update talkgroups by going to MENU PTT Talk Groups Refresh Talk Groups Configuring the PTT Input PTT cal...

Page 26: ... some modems can be used in more than one geographic area with some reduction in the bands available When ordering the DZMx it is essential that the version with the correct regional modem is ordered Please contact tech flightcell com for more information on the appropriate modem for your operational area Internal Iridium Modems The following satellite modems may be installed in the DZMx One or tw...

Page 27: ... DZMx Connect go to Settings Hardware External Debug Port Config The following are currently supported Rhotheta Direction Finder Erickson AWTC ETM Cycle Counter AFDAU Automated Fire Data Acquisition Unit SIM Cards SIM cards may be required for operation of the DZMx modems A SIM card is required for a DZMx cellular modem A SIM card is required for an internal Iridium 9523 if it is to be used for ph...

Page 28: ...r Iridium service To transfer the SIM card to your ISP please contact Flightcell International at tech flightcell com advising the serial number of your DZMx and the name of your ISP Configuring Modems The DZMx is configured prior to shipment with default settings for the installed modems However you may need to check and modify these settings This is done in DZMx Connect Go to Settings Modems Con...

Page 29: ...s necessary to set the APN Access Point Name for the cellular modems to allow the modem to use cellular data services You will need to determine the APN for your cellular provider this can normally be obtained from their website This is often but not always Internet Enable or disable data Use this setting to enable or disable data services for the selected modem Data Roaming If a cell modem is ope...

Page 30: ...though a faster service is available on 4G The cellular bands used by the DZMx can be configured to improve its performance On DZMx Revisions 5 0 or later the cell modems can be locked into 4G using the DZMx Advanced Band Select settings To lock to specific services and bands Go to Settings Preferences Regional Cell Modem Region and select Advanced Band Select Go to Settings Preferences Advanced B...

Page 31: ...e band select Only use Advanced Band Select on Revision 5 DZMx or later Locking into LTE only will generally give better data speeds but if the LTE coverage in your area is not as extensive as 3G you may need to select both 3G and 4G bands Lower frequency cellular bands in the range 700 to 850 MHz will generally give better service than higher frequency bands ...

Page 32: ...NVIS A versions Most DZMx installations will be NVIS B the NVIS A versions are only required by some military organisations mainly in the USA The NVIS A versions use NVIS A LEDs in the display for night operation only using NVIS B LEDs during day operation and use NVIS A LEDs in the keypad Manual Backlight Control from the DZMx keypad The operator can access the lighting settings from the Head Men...

Page 33: ...d Head Diagnostics Adjust the dimmer control through its full range and observe the Input value changing it should swing between approximately 0 and 3200 for a nominal input range of 0 to 28 volts however a smaller range may be used External Lighting Control Modes There are a range of ways an external dimmer control can operate The DZMx has several modes designed to provide for the different optio...

Page 34: ...hting Config press ENTER Select Ext Lighting Night Low press ENTER Set the dimmer control to its minimum Adjust the following settings Set Display brightness lo to desired brightness Set Keypad brightness lo to desired brightness Select the Input calib hit Enter value row and press the ENTER key to sample the input Note this value may be overridden by using the LEFT and RIGHT keys to adjust 3 Exit...

Page 35: ... mode but in step 6 above set the dimmer control to the detent position In this configuration the backlighting will now switch to the Day brightness settings once the input is below the detent Note A hysteresis band is used to prevent the accidental switching into day mode the size of which can be adjusted using the Ext Lighting Hysteresis setting see Input Filtering section below ...

Page 36: ...light Mode to Night Day using the LEFT or RIGHT arrow keys Follow steps 5 to 7 as per Configure variable night mode above setting the dimmer control and night brightness as desired for the night range Repeat the steps 5 to 7 above for configuring Ext Lighting Day Low High settings as desired for the day range Note The voltage values in the diagram below are examples only The actual values when the...

Page 37: ...Input Filtering The Ext Lighting Hysteresis setting is in units of ADC counts as per the input value and it is used to filter out small changes on the input to avoiding flickering It is also used in the Ext B light Mode Day Night mode to help prevent accidental switching into Day mode as illustrated in the diagram Night Day Switching Margins To avoid potentially hazardous mode switching e g from n...

Page 38: ...itch or router which operates as the DHCP server The DZMx will be allocated an IP address by the connected switch or router A static IP address may be required in some network configurations These options can be selected using DZMx Connect or on the DZMx control head To determine the IP address the DZMx is using go to MENU Diagnostics Menu About DZMx DHCP Server Mode Configuration The DZMx operate...

Page 39: ...ary Ethernet Connection The secondary Ethernet can be configured in the same way as the primary Ethernet Controlling IP packet forwarding The DZMx provides a mechanism to enable disable IP forwarding between Wi Fi and Ethernet to allow wired networks to be isolated from the wireless network This is configured by going to Settings Network Firewall When enabled data can be forwarded between the DZMx...

Page 40: ...i service on the DZMx DZMx Wi Fi allows the DZMx to act as an access point to connected devices enabling the DZMx to be used to route DZMx data connections to connected devices including PCs Tablets Smartphones Medical devices Other specialised devices Provide WPA2 encryption security to wireless devices Starting WiFi If the DZMx is WiFi capable and the Wi Fi licence has been activated the WiFi se...

Page 41: ... press on the MODE key When Bluetooth is enabled the Bluetooth icon will appear at the top right of the screen on the front panel Bluetooth can be disabled in the DZMx Control Head menu Go to MENU Hardware Config Wireless and Networks Bluetooth Enable Pairing Check that the Bluetooth icon is showing on the DZMx display Make the DZMx Bluetooth discoverable using the DZMx Connect Go to Connectivity ...

Page 42: ...ssful the DZMx will display a mobile phone icon in the top left corner of its display see Pairing above If a user receives or initiates a call on the paired mobile device the audio will be routed to from the ICS Headset Note The auto connect functionality may vary depending on the mobile device and the level of support provided by the operating systems A high degree of variability is present acros...

Page 43: ...radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 44: ...nts tracked The DZMx tracking system provides information on Position altitude heading and speed Flight state on ground hovering flying unknown To use the DZMx tracking capability it is necessary to enter a contract with a tracking service to receive process and display tracking information The DZMx must then be configured to work with that tracking service Position reports are sent at intervals T...

Page 45: ...ly enabled Locking the Tracking Menu By default some tracking settings are unlocked and can be altered by the crew to change the main tracking timers To lock the tracking menu so the crew cannot change these settings On the DZMx Control head go to MENU Tracking Lock Tracking Menu On DZMx Connect go to Settings Tracking General The Tracking Menu will be hidden from view when the DZMx is next restar...

Page 46: ...ts and degrees relative to true north rather than magnetic north Clock the current time and date is shown in UTC not local time TTAF Total Time Airframe DFT Daily Flight Time Trip Current trip time To set the top line display using the DZMx keypad Go to MENU Display Setup Menu Top Line Options or DZMx Connect Go to Settings Preferences Top Line Options Tracking Providers Flightcell does not provid...

Page 47: ...m network Using the Short Burst Data service SBD or SMS If you wish to enable a particular modem for tracking ensure the Use for Tracking modem setting is enabled and additionally the SBD Enable modem setting is enabled for any Iridium modems Preferred Transmission Mode The DZMx can prioritise the available networks used for sending tracking messages This is particularly useful to allow you to pri...

Page 48: ...our cellular service provider or from their website The normal default APN is Internet Enable Data This setting must be set to On There must be a data connection active to send tracking messages to an IP port Configure in DZMx Connect Go to Settings Tracking Transmission IP address Your tracking provider will advise you what IP address setting to use An example is 123 123 5 6 IP port Your tracking...

Page 49: ...mer The time in minutes between sending automated position reports while in flight 15 seconds for HD tracking On Ground Timer The time in minutes between sending automated position reports while on the ground not in flight Taxiing Timer The time in minutes between sending automated position reports while taxiing ...

Page 50: ... up to 1 tracking message to be sent every 15 seconds by the DZMx while a data connection is available Off Turns HD tracking off reverts to the periodic tracking interval as set up in Periodic Events Cell HD Turns HD tracking on for cell sending position reports every 15 seconds If messages start to queue due to being in a poor signal area then the frequency of the tracking messages will drop back...

Page 51: ...e tracking service or A mission mark this prompts the user to press one of the coloured keys on the DZMx keypad then the mission number this is sent to the tracking service or Mark and text contacts send a position and message from the DZMx message library to one or more SMS recipients and optionally the tracking service The recipients for each message are designated individually by editing entrie...

Page 52: ...ver is not enabled then the tracking rate will drop to using the standard Periodic Timer rate whilst the aircraft speed is 0 but will switch back to HD as soon as the aircraft is moving again Engine Start and Stop Events The DZMx can be configured to send an event report when the engine starts and stops Typically this is triggered by the transmission oil pressure warning light circuit See DZMx Inp...

Page 53: ...end application allows operators to suspend tracking while the aircraft remains within a set geographical radius This enables position reports to be supressed while the aircraft is operating in a localised area e g during crop dusting or Airwork operations Moving outside the geofence perimeter will cause geofence mode to be cancelled and normal tracking to resume Whilst within the perimeter period...

Page 54: ...ven inputs can be installed with the optional Input Expansion Card IEC DZMx Inputs The DZMx general purpose inputs GPIs can be used to indicate some event or state on the aircraft A standard DZMx has five inputs with another seven inputs available on the optional DZMx Input Expansion Card IEC An input may be used for a range of functions Uses include Indicating an event including but not limited t...

Page 55: ...n be configured as either a standard input see Configuring Inputs below or as a cockpit dimmer control for the DZMx keypad LCD brightness Configuring the inputs These inputs can be set up on either the DZMx keypad at MENU Hardware Config Input Configuration or using DZMx Connect Settings Inputs In practice it is easier to set them up using the DZMx control head as the DZMx reports the status of th...

Page 56: ...operator is dialling or in a call Incoming Call Alerts the operator when there is an incoming call PTT Transmitting A device in the talk group is transmitting Received Msg Alerts the operator when a text message has been received or a call has been missed Power Indicator Alerts the operator when the DZMx is powered on To select the allocation of the outputs and the blink pattern using the DZMx con...

Page 57: ...essure millibars Pressure altitude reference to 1013 25 millibars Disclaimer The Flight Data Recording system in the DZMx uses a six degree of freedom sensor fusion technique and thus all pitch and roll values output are a best estimate based on measured angular rate prone to drift and estimated gravity vector which can be distorted by accelerations This must not be used for navigational or contro...

Page 58: ...Mx logs GPS data at one second intervals including aircraft position speed heading and altitude and GPS quality metrics Transmitting Log Data The DZMx can automatically transmit log data using the DZMx Email Outbox feature Using DZMx Connect go to Settings Preferences Logging Email Reporting to specify which logs are transmitted and to activate automatic emailing of the logs DZMx Email Outbox The ...

Page 59: ...ce timers also known as a Hobbs Meter The DZMx can record and transmit the following TTAF Total Airframe Flight Time hrs This records all flight time in hours and tenths of hours The aircraft airframe hours are entered on installation and this is incremented during every flight DFT Daily Flight Time This is a continuous timer that records flight time in hours and tenths of hours It must be manuall...

Page 60: ...dually To reset the DFT and counters Using the DZMx UI menu go to MENU Timers DFT Reset DFT Selecting YES will reset the DFT timer and the landing and engine start counters Using DZMx Connect go to Flight Flight Timers Reset If a maintenance email address is specified a maintenance email or emails will be sent automatically before the counters are reset Check Due Counter The DZMx can record hours ...

Page 61: ...flight timers are sent in the take off message to the tracking provider The TTAF DFT Trip Lands and Starts are sent in the landing message to the tracking provider The Trip counter is not included in the email since this is automatically reset on every flight Maintenance Email Attached Data File Attached to the maintenance email will be a JSON formatted file which will contain all the maintenance ...

Page 62: ... daily timers are reset Using DZMx Connect go to Settings Preferences Hobbs and Maintenance to modify the following settings Count Engine Starts This can be toggled on off Count Landings This can be toggled on off Check Due Hours Min 1 Max 10000 Enter the Flight Hours Check Due Warning Hrs Min 0 Max 10 Adjust using the scroll bar or type in the number of hours Send in Tracking Msg This can be togg...

Page 63: ...lds in the form Select the symbol A Form Editor window will open Enter a unique Field Name select whether the form must be completed Mandatory or does not have to be completed Optional If Mandatory is selected the form cannot be completed unless all the mandatory fields are filled in Type Select the response e g On Off Yes No Number or Text Note The Number and Text fields have a maximum length of ...

Page 64: ...sabled Tag Forms in the forms list prefixed with minus character are disabled forms An operator cannot fill in a disabled form and disabled forms will never be triggered A disabled form can be enabled by an Operator and an installer Select the form by pressing ENTER Form Enabled Confirm by selecting either No or Yes Triggered Tag Forms in the forms list prefixed with a asterisk character have been...

Page 65: ...complete a form if any mandatory fields have not been filled in To remind the operator to complete the form s Form Entry Required will appear across the top line of the main screen Use the MODE key to access the triggered forms Pressing the Mode key will cycle through each triggered form Complete each form then select the MODE key again to exit to the main menu screen If the DZMx is powered off be...

Page 66: ...y selecting either No or Yes Note Disabling a form will cancel any active trigger on that form It will also cause the flight hours to reset to 0 for that form If the trigger type is set to Flight Time Flight time will only start to accrue for the form when it is re enabled Export Form History Exports the data for the selected form to a USB stick If no USB stick is inserted or if there is no data t...

Page 67: ...info flightcell com We will send you a licence file To load the licence file Open DZMx Connect and enter the installer password Go to About this will show a list of licences currently installed on the DZMx Click on UPLOAD LICENSE and follow the prompts Restart the DZMx DZMx Applications These following licensed applications are described in this manual DZMx Wi Fi this application activates the Wi ...

Page 68: ...port firmware and save it to a USB memory stick If using DZMx Connect upgrade method download the firmware directly from https www flightcell com support firmware and save it to the PC or laptop hard drive Ensure the aircraft is on ground power or there is enough battery power to run the DZMx for at least 1 hour DZMx draws approximately 1A at 28VDC To perform the upgrade Using the DZMx USB port In...

Page 69: ... tracking over IP function Performs a check on the settings used to enable Tracking over IP as well as a real time test using the configured tracking provider gateway Local Network Info Contains diagnostics on the status of the Bluetooth and WiFi connections External Inputs Contains diagnostics on the current status of the DZMx General Purpose Inputs Export System Log Files Exports system log file...

Page 70: ... will receive a notification and they will be able to remotely access the DZMx The DZMx will operate normally throughout this process To establish a VPN connection Using the DZMx keypad go to MENU Remote Assistance Connect VPN then press ENTER or Using DZMx Connect select Remote Access and toggle Connect to ON If the connection is successful a VPN connection online message will be displayed If the...

Page 71: ...ection This menu option resets and updates the Remote Assistance connection and you will typically be directed to do this by Flightcell Support Enable at Start up This menu option forces the DZMx to automatically establish a VPN Remote Assistance connection on start up This feature is useful for long term monitoring and diagnosis ...

Page 72: ... www flightcell com resources Technical support For technical support contact Flightcell By email tech flightcell com By phone 64 3 545 8651 ContactDetails Mailing Address Flightcell International Limited PO Box 1481 Nelson 7040 New Zealand Physical Address Flightcell International Limited 98 Vickerman Street Nelson 7010 New Zealand Telephone 64 3 545 8651 Fax 64 3 548 8091 Email info flightcell c...

Page 73: ...tcell manufactured items only Any ancillary items may be covered by individual manufacturer warranties The warranty is void if any labels are removed or if it is determined that your DZMx has been Connected to a power supply delivering more than 32 Volts Connected with reverse polarity Installed in direct contravention to the guidelines outlined in the Flightcell DZMx Installation and Configuratio...

Page 74: ...l Iridium GPS antennas CNC_00100 BNC plug R A 50 OHM Crimp 1 CNC_00101 TNC plug R A 50 OHM Crimp 1 CNP_00029 Single Antenna TNC Connector Kit Single Iridium antennas CNC_00101 TNC plug R A 50 OHM Crimp 1 CNP_00030 Flightcell DZM Remote Head Connector Kit Flightcell DZMx Remote Head CNC_00046 Metal Back shell for DA Size connectors Straight 15 way 1 CNC_00048 DA15S M24308 Crimp and Poke Socket with...

Page 75: ...0002 TNC crimp plug RG58 2 CNC_00001 BNC crimp plug RG58 1 IDP_00012 Flightcell USB Ethernet Military Connector Box 1 CNC_00059 D38999 26WB 35SN Straight plug 1 CNC_00058 M85049 38S 11A D38999 Strain Relief B Shell 1 CNK_00038 Triple Antenna BNC TNC TNC Connector Kit CNC_00001 BNC crimp plug RG58 1 CNC_00002 TNC crimp plug RG58 2 CNK_00039 Flightcell Iridium Modem Connector Kit Flightcell Iridium ...