SYSTEM TRIP CODE TROUBLESHOOTING

Should an application or system problem occur, built-in diagnostics will protect the system . The red “FAULT” light on the front 

of the controller will flash and a fault condition will be shown on the display . In some cases, the system will shut itself off until 

corrective action has been taken . Fault codes and the recommended corrective action for each are listed in the following 

table . To view the trip codes in the recent trip log, press and hold the UP & DOWN keys at the same time for 1 second . The 

log will show the last 20 trips as well as the time in days, hours & minutes since the trip occurred .  (Note: the trip time will only 

increment while the drive has power .) If no trips have been recorded, “No Fault” will be displayed in the log .  

Fault

Possible Causes

Corrective Action

KEY:

APPLIES ONLY TO TRANSDUCER

APPLIES ONLY TO PRESSURE SWITCH

APPLIES TO EITHER OPTION

Short circuit

Shorted motor cables

Check motor wires and drop cable for shorts or bad connections

Shorted motor

Replace motor

Damaged wire insulation

Check drop cable for insulation damage

Internal hardware short

If motor is disconnected and the fault is present when reset, replace drive .

Locked Rotor

Motor/pump misaligned

Verify  Pump is mounted flush on motor mounting flange .

Bound pump

Check for debris n pump

Transducer Found 

(Switch Control)

Drive set for Switch control, but a 

transducer signal was detected.

Change drive control choice from Switch to Transducer in Control 

Choice menu

Shorted Transducer 

(Transducer Control)

Drive has detected a short circuit between 

S1 & S2 terminals

Internal short of transducer .  Replace transducer .

Switch is hooked up between S1 & S2 

Replace switch with transducer .

Open Transducer 

(Transducer Control)

Transducer lead not connected properly to 

transducer (or cut)

Check transducer lead connection and/or replace transducer lead wire .

Loose connection on terminals S1 & S2

Check transducer lead connection at drive terminals S1 & S2

Transducer lead wire backwards at S1 & S2 

terminals

Switch transducer leads at S1 & S2

Transducer failed as an open circuit

Replace transducer

Deadhead 

(Switch control)

Pump running against a closed discharge. Make sure that there is not a valve closed or obstruction  

between the pump and pressure switch

Damaged or clogged pressure switch

Check continuity across switch contacts without wire connected  

and replace and/or clean pressure port.

Deadhead sensitivity incorrect

Adjust deadhead sensitivity in Underload Protection menu

Deadhead 

(Transducer Control)

Pump running against a closed discharge .

Make sure that there is not a valve closed or obstruction  

between the pump and pressure transducer

Deadhead sensitivity incorrect

Adjust deadhead sensitivity in Underload Protection menu

Clogged pressure transducer

Check transducer for pressure port and clean

Damaged or inoperative transducer

Replace transducer

Low PSI 

(Transducer Control)

Pipe has not filled 

Reset pipe fill mode in Menu #10 Control Settings and increase fill time if 

necessary .

Valve closed between pump & transducer

Open valve between pump & transducer .

Clogged Pressure transducer

Check transducer for pressure port & clean

Damaged or inoperative transducer

Replace transducer

Dry Well

Over pumped/dry well

Wait for well to recover and automatic restart timer to time out

Blocked pump screen

Clear pump screen

Broken pump shaft

Replace pump shaft (or pump)

Worn pump

Replace pump

Under Voltage

Low line voltage

Check line voltage Report low voltage to the power company

Power was removed from Drive

Check voltage is present on all input lines & connections secure

(Color) Leg Open

Loose connection

Check connections on drive motor terminals for leg specified

Defective splice

Check all splice connections on drop cable for leg specified

Defective cable

Check continuity of drop cable for leg specified

Open motor winding

Replace motor

Overheated

Excessive heating of Drive

Check that the ambient temperature is not above 125°F
Check for obstructed or inoperable fan
Check for blocked vents

Broken Pipe

Drive has been running without going into  

standby mode for set time

Check for broken or leaking pipe and repair as necessary

Application calls for long run time

Increase broken pipe run time in Advanced Feature menu
Turn off Broke Pipe protection in Advanced Feature menu

External Trip

Contacts closed on "Alarm In" terminals

Check condition of switch wired into "Alarm In" terminals

Summary of Contents for Commander Pro

Page 1: ... pressure Key features of the drive controller include Can use either a pressure switch no snap action or a 4 20mA transducer as the pressure control At initial power up the controller detects whether a switch or transducer is connected and automatically sets the control choice Constant water pressure with a wide range of settings 30 80 psi Note The maximum obtainable system pressure is limited by...

Page 2: ... prevent mechanical damage which could produce serious electrical shock and or equipment failure Pump is designed to pump cold ground water that is free of air or gases Decreased pump performance and life expectancy can occur if the ground water is not cold 86ºF 30ºC or contains air or gases Pump and controls must be securely and adequately grounded as specified in section 250 43 item A of the U S...

Page 3: ... in equipment and property damage as well as possible injury Always install a pressure relief valve capable of passing full pump flow at 100 PSI Install the pressure relief valve between the pump and pressure tank PRESSURE SETTING GUIDE System Pressure at Pressure Sensor Pressure Tank Setting PSI 2 psi 25 18 30 21 35 25 40 28 45 32 50 factory set 35 55 39 60 42 65 46 70 49 75 53 80 56 Pressure Rel...

Page 4: ...ve access to 230V electrical supply and to the submersible motor wiring 6 Do not expose the drive to water spray greater than 30 from vertical Note Installations that require larger than 6 AWG wire will require an external junction box Run 6 AWG from the drive to the junction box and make external connections to the appropriately sized wire with wire nuts WIRING SIZING CHART Maximum Wire Lengths C...

Page 5: ...D Black BLK Yellow YEL and W Submersible 3 Phase or 3 Wire 1 Ph motors follow colors as marked Red to RED Black to BLK Yellow YEL and Green Ground wire W Submersible 2 Wire 1 Ph motors Connect motor leads to BLK YEL and Green Ground wire W Above Ground Motor 3 Phase Only L1 to RED L2 to BLK L3 to YEL and Green Ground wire W Verify motor rotation to avoid damage to pump motor L1 L2 RED BLK YEL IN O...

Page 6: ...ightening the thumbscrew finger tight START UP OPERATION Apply power to the controller The display should briefly show Please Wait Initializing and then read Press Enter to Begin Set Up Pressing ENTER button will begin taking you through the quick set up menu where you can select Pump type Submersible or Above Ground Motor type Three Phase 3W Single Phase if option is available Maximum Motor Curre...

Page 7: ...imer low level switch etc can be used to trip the drive with an External Fault trip For this connection to work properly the Alarm in Relay contact condition setting in the Advanced Features Menu must be set to match the switch position to activate the drive Example An irrigation timer closes a contact to single the drive to run the Alarm In Relay setting should be set to NC Normal Closed for the ...

Page 8: ...eter press the EDIT button followed by the UP and DOWN buttons to set or choose the new value Once the new values is set press the ENTER button to accept the new value or the ESCAPE button to discard the change Once you are done viewing and changing the parameters press ESCAPE to return to the home screen For further information to change these parameters please call Technical Support at 800 742 5...

Page 9: ...w the BM current the drive will ramp up for the BM duration regardless of switch state to create an overpressure drawdown Set bump mode duration Sets the time duration of the ramp up for a bump in PSI 5 to 2 0 sec Default 0 5 sec By increasing this duration time the amount of overpressure for drawdown can be increased Caution Increasing this time too much has the potential of creating a high over ...

Page 10: ...n or normally closed Default NO The state of the relay changes when the drive trips Typically not for use in most residential applications Powered by Generator No Yes Default No Set the drive circuitry to expect power delivered from a gas driven generator Depending upon application a 5 10 pressure drop of can be experienced when the drive is running the pump motor at full speed Ramp up sensitivity...

Page 11: ...uit Replace transducer Deadhead Switch control Pump running against a closed discharge Make sure that there is not a valve closed or obstruction between the pump and pressure switch Damaged or clogged pressure switch Check continuity across switch contacts without wire connected and replace and or clean pressure port Deadhead sensitivity incorrect Adjust deadhead sensitivity in Underload Protectio...

Page 12: ...ith higher flow rating if head requirement is still satisfied Temperature in the controller is too high If the controller s heat exchanger becomes too hot the controller will reduce the output frequency to the motor to lower the power consumption Make sure there is at least 4 inches of room around the controller for movement of air Avoid direct sunlight Reduce ambient temperature below 104 F 40 C ...