DANGER

 Never enter the water 

either wading, swimming or in a boat with the 
pump power on, as this may result in severe 
electrical shock. 

 Read these warnings and instructions 

carefully. Failure to follow could result in serious bodily 
injury and/or property damage.

 

 Electrical installations 

shall be in accordance with National Electric 
Code (NEC) and all applicable local codes 
and ordinances. A licensed electrician should 

perform installation.

 

DANGER

 “NO SWIMMING” AND 

OR WARNING SIGNS SHOULD BE POSTED PER 
STATE AND LOCAL CODES. 
Please affix included warning label to power 

receptacle or junction box.

 

 System furnished with a 

100ft power cord with three prong GFI plug. – 
Must connect to properly grounded receptacle 
of grounding type. Do not remove ground 

pin on plug. Do not extend the cord length by splicing or 
with an extension cord.

 

 FAILURE TO CONNECT 

THIS UNIT, WITH THE GFI, TO A PROPERLY 
GROUNDED RECEPTACLE MAY RESULT IN 
SEVERE ELECTRICAL SHOCK.

 

 Be sure system is connected 

to a circuit equipped with a fuse or circuit 
breaker of ample capacity.

 

DANGER

 Always disconnect power 

source before performing any work on or 
near the motor or its connected load. If the 
power disconnect point is out-of-sight, lock it 

in the open position and/or tag it to prevent unexpected 
application of power. Failure to do so could result in fatal 
electrical shock or bodily injury.

 

DANGER

 DO NOT handle pump with 

wet hands or when standing in water as 
fatal electrical shock could occur. Disconnect 
main power supply before handling system 

for any reason.

 

 Protect the power cable 

from coming in contact with sharp objects, 
oil, grease, hot surfaces or chemicals. DO 
NOT kink the power cable. If damaged 

replace immediately.

 

 NEVER leave the control 

box, fused disconnect switch, or covers open 
(either partially or completely) when not 
being worked on by a competent electrician 

or repairman.

 

DANGER

 Always use caution when 

operating electrical controls in damp areas. 
If possible, avoid all contact with electrical 
equipment during thunderstorms or extreme 

damp conditions.

 

 Install all electrical 

equipment in protected area to prevent 
mechanical damage which could produce serious 
electrical shock and/or equipment failure.

 

DANGER

 DO NOT use this system to 

pump flammable liquids such as gasoline, fuel 
oil, kerosene, etc. Failure to follow the above 
warning could result in property damage and/

or personal injury.

 Do not pump water above 120 degrees 

Fahrenheit.

 Water leaving nozzle is at high velocity 

and can cause bodily injury if contact is made.

 

 This unit not tested for use 

in swimming pool areas.

 GFI plug must be oriented with cord 

coming out the bottom and protected from direct rainfall.

INSTALLATION INSTRUCTIONS

1.  Only install this system in ponds where no swimming, 

wading, boating or fishing is allowed while fountain is 
operating. Disconnect power to pump before fishing or 
entering the water.

2. Post appropriate warning signs per local and state codes.
3. Inspect pump system for damage before installing in 

pond. Check that all bolts and screws are tight. Check for 
any bent prongs or a cracked case on the GFI. 

4. The unit ships with one spray nozzle attached. To change 

to one of the other 2 nozzles, remove the 4 screws from 
the nozzle then replace with desired nozzle. Refer to 
Figures 1, 2 & 3 for spray pattern appearance.  Nozzles 
are marked “This side up.” Make sure the o-ring is 
seated in groove before installing nozzle. Tighten screws 
until seated, approximately 10 to 12 in-lbs.

5. Attach nylon anchor ropes to 2 eyebolts located at top 

of screen. Secure (make sure rope is tight) to weights 
placed on pond floor or stakes on pond shore. When 
using weights to anchor the pump, place weights 
approximately 10 feet from unit, 180 degrees apart.

Summary of Contents for FPS0501

Page 1: ...o comply with instructions could result in personal injury and or property damage Retain instructions for future reference General Safety Information Carefully read and follow all safety instructions in this manual and on pump Keep safety labels in good condi tion Replace missing or damaged safety labels This is a SAFETY ALERT SYMBOL When you see this symbol on the pump or in the manual look for o...

Page 2: ...trol box fused disconnect switch or covers open either partially or completely when not being worked on by a competent electrician or repairman DANGER Always use caution when operating electrical controls in damp areas If possible avoid all contact with electrical equipment during thunderstorms or extreme damp conditions Install all electrical equipment in protected area to prevent mechanical dama...

Page 3: ...Water Lily An eye catching combination spray Item 2C T h i s s i de up IL0537 T h i s s i de up T h i s s i de up Figure 2 Sky Cannon A dramatic single plume of water Item 2B IL0537 T h i s s i T h i s s i de up Figure 3 Water Trumpet A symmetrical inverted bell shape Item 2A IL0535 Pond Pump Float Nylon rope secured to weights can be attached to stakes on shore 2 Required 5 Feet Minimum Depth App...

Page 4: ...or rope loose Check anchor rope and re attach if necessary Item Qty Part No Description 6 Screw 10 x 3 4 Slotted Head or Pan Head Sheet Metal Screw 18 8 Stainless Steel 2A 1 021617 Nozzle Water Trumpet 2B 1 021618 Nozzle Sky Cannon 2C 1 021619 Nozzle Water Lily 3 1 021622 O Ring AS568A 041 3 ID x 3 18 OD 4 6 021628 Bolt SS 1 4 20 x 3 4 5 6 021629 Lockwasher 1 4 6 1 021707 Mounting Flange 7 1 02291...

Reviews: