FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
121
of
170
8
Unit change (from first to second unit)
9
Unit change (from second to first unit)
10
Keylock enable
11
Keylock disable
12
Dynamic Start
13
Dynamic Reset
14
M+ key usage
15
Totalization Print (MRC key and Print key)
16
Totalization Cancel.
17
SmartAPP Start
18
SmartAPP Reset
19-23
Not used
24
Basic peak enable
25
Basic peak disable
26
Hold enable
27
Hold disable
40027
R
2
Commands status
0
None
1
Command is processing…
2
Command is successfully.
3
Command failed.
40029
R/W 12
Reserve
40041
R
2
Status of Inputs
Bit
Definition
B0
Input-1
0
– Passive
1
– Active
B1
Input-2
B2
Input-3
B3
Input-4
40043
R/W 2
Status of Outputs
B0
Output-1
0
– Passive
1
– Active
B1
Output-2
B2
Output-3
B3
Output-4
B4
Output-5
40045
R/W 2
Basic weighing
Filling
Checkweighing
Classifying
Peak holding
Setpoint 1(High)
Target
Target
Target
Follow
40047
R/W 2
Setpoint 2(High)
Coarse
Low
- - Low
Mid Decr.
40049
R/W 2
Setpoint 3(High)
Fine
High
-Low
End Decr.
40051
R/W 2
Setpoint 4(High)
TareMin
Empty
+High
Stop
40053
R/W 2
Setpoint 5(High)
TareMax
Not used
++High
Alarm
40055
R/W 2
Not used
Empty
Not used
Empty
Empty
40057
R/W 2
Setpoint 1 Low
Only available for Threshold and Window feature.
Refer to sub-block 36-, page 61 to see the availabilities.
40059
R/W 2
Setpoint 2 Low
40061
R/W 2
Setpoint 3 Low
40063
R/W 2
Setpoint 4 Low
40065
R/W 2
Setpoint 5 Low
40067
R
2
Only available for Peak hold application.
Refer to Section 10.4, page 88.
1
st
Peak value
40069
R
2
2
nd
Peak value
40071
R
2
3
rd
Peak value
40073
R
2
4
th
Peak value
40075
R
2
5
th
Peak value