10100 20
Not used
Empty
Not used
Empty
Empty
10101 21
SetPoint-1 Low
Only available for Threshold and
Window feature.
Refer to sub-block 36-, page 61 to see
the availabilities.
10110 22
SetPoint-2 Low
10111 23
SetPoint-3 Low
11000 24
SetPoint-4 Low
11001 25
SetPoint-5 Low
11010
11110
26
30
Not used
11111 31
Use the Expanded Command list
(Refer to Table 16-3)
B37 ...
B33
Read Data
Selection
00000 0
Actual weight (if the indication is in Net)
00001 1
Gross weight
00010 2
Tare weight
00011 3
ALL Status (Refer to Table 16-1)
00100 4
Calibration Status (Refer to Table 16-2)
00101 5
Last print value
00110 6
Quantity of M+
00111
01010
7
10
Not used
01011 11
CN (Label number)
01100 12
Quantity of M+
01101 13
Grand Total
01110 14
Not used
01111 15
B. weighing
Filling
C.weighing
Classifying
Peak hold
Set Point-
1
Target
Target
Target
Follow
10000 16
Set Point-
2
Coarse
Low
--Low
Mid Decr.
10001 17
Set Point-
3
Fine
High
-Low
End
Decr.
10010 18
Set Point-
4
TareMin
Empty
+High
Stop
10011 19
Set Point-
5
TareMax Not used
++High
Alarm
10100 20
Not used
Empty
Not used
Empty
Empty
10101 21
SetPoint-1 Low
Only available for Threshold and
Window feature.
Refer to sub-block 36-, page 61 to see
the availabilities.
10110 22
SetPoint-2 Low
10111 23
SetPoint-3 Low
11000 24
SetPoint-4 Low
11001 25
SetPoint-5 Low
11010
11110
26
30
Not used
11111 31
Use the Expanded Command list
(Refer to Table 16-3)
B32
New CMD
Toggle
Apply commands which are listed in this table.
B31-B0
B37-B33 bits defines the usage of this Dword.
(1) Write this command after writing values to Low Dword of RxPDO then apply this command with New
CMD.