Access to Alibi records:
1. Go to the parameter [ 8-- METROLOGY] main block in set up.
2. Press key 4 times to access parameter 813.
3. Select the suitable criteria by pressing
or
keys which are NUM (Alibi number),
DATE (weighing date), NET (net weight), GROS (gross weight), TARE (tare weight) or
CN (consecutive number).
Alibi records will be displayed in sequence:
1. Alibi record number
2. Date
3. Time
4. Gross weight
5. Net weight
6. Tare weight
7. Consecutive number
Search with Alibi record number:
1. Press
key after selecting NUM in parameter 813.
2. Press numerical keys to enter alibi number in the printout data and press
key. You
may navigate in the alibi memory with
or
keys after entering alibi number.
3. The weighing data in the alibi memory is indicated on the display.
4. Press
key to print this record and the previous nine weighing.
5. Press
key 4 times to return operation.
Search with date:
1. Press
key after selecting DATE in parameter 813.
2. Press numerical keys to enter date in the printout data and press
key. The date
format entry should be as in the operation. e.g. date entry should be DDMMYY if
parameter 251 is set to DMY. You may navigate in the alibi memory with
or
keys after entering the date.
3. The weighing data in the alibi memory is indicated on the display.
4. Press
key to print this record and the previous nine weighing.
5. Press
key 4 times to return operation.
Search with weight value:
1. Press
key after selecting NET, gross or tare which is suitable in parameter 813.
2. Press numerical keys to enter weight value in the printout data and press
key.
3. The alibi record is indicated on the display.
4. Press
key to print this record and the previous nine weighing.
5. Press
key 4 times to return operation.
Transfer all Alibi records:
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 5 times to access parameter 814.
3. Press
or
keys to select PRNT and press
key to start transferring.
4. Or you may stop transferring by pressing
key.
About Alibi Memory:
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 6 times to access parameter 815.
3. Press