FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
60
of
170
[ 34A UNIT
: USE
]
Unit key locking
USE
LOCK
:
:
Not locked
Locked
[ 34B G/N KEY
: USE
]
G/N key locking
USE
LOCK
:
:
Not locked
Locked
[ 34C PT KEY
: USE
]
Preset tare key locking
USE
LOCK
:
:
Not locked
Locked
[ 34D HIGH
: USE
]
High resolution key locking
USE
LOCK
:
:
Not locked
Locked
[ 34E CLEAR
: USE
]
Clear key locking
USE
LOCK
:
:
Not locked
Locked
[ 35-
DIG INPUTS
]
DIGITAL INPUTS
(appears if option installed)
Press key or
key again to enter this menu.
Or press
key to go to the next sub-block.
351
INPUT 1
: NO
]
Input 1
Page 95,
NO
ZERO
TARE
CLR
PRNT
LOCK
DYST
DYRE
PEAK
HOLD
FBUS
:
:
:
:
:
:
:
:
:
:
:
Not used
Zeroing
Taring
Clear
Print
Key lock
Dynamic weighing start
Dynamic weighing reset
Basic peak hold at basic weighing
Hold at basic weighing
Remote Input over fieldbus or BSI command.
[ 352
INPUT 2
: NO
]
Input 2
Page 95,
:
[ 353
INPUT 3
: NO
]
Input 3
Page 95,
:
[ 354
INPUT 4
: NO
]
Input 4
Page 95,
: