8 I
DENTIFICATIONS
APPLICATION
:
To enter identification data to the instrument to printout or to transfer the data together with
identification data.
RELATED PARAMETERS: Sub-block 37- .
FT-112(D) Panel weighing indicator has 2 identification keys ID1 and ID2 positioned under the display for
storing identification data. Each identification key has an alphanumeric identification name and data. The
identification data can be saved into the ID1 and ID2 memories, each has 500 pieces 32-character
identification data record size.
The identification data can be entered via keys or selected from ID memory to transfer together with the weight
value. The length of identification name can be maximum 16 characters and the length of identification data
can be up to 32 characters. ID names are entered in the programming mode as a header of ID.
ID data in the memory can be linked to the PT, SET and/or APW memory records. This feature gives
advantage to select the related records automatically by selecting ID from memory. For example, if SET
memory is linked to ID1 memory, the 123
th
record in the SET memory is loaded automatically after loading
123th record from ID1 memory.
The descriptions below are given for ID1 key. The usage of ID2 is the same.
Enter Identification data via alphanumeric keys
1. Press the identification key
.
2. Enter the identification data up to 32 digits via alphanumeric keys.
3. Confirm with
key.
Record Identification data into the ID memory
1. Press
key for more than 2 seconds in weighing operation. The [ MEMORY ] prompt will be
displayed.
2. Press
key to enter ID1 memory. The last used memory code appears as [ID1 : 123 ] .
3. Enter the memory code numerically and press
key.
4. The ID code and identification data appears on the display.
5. Enter the new alphanumeric ID data up to 32 digits and press
key.
6. The following memory code shown on the display to go on the ID data entry. You may press
key
to enter ID data into the following memory or you may repeat the procedure from item 3 to enter the
new memory record number.
7. To return the operation press
key.
Select Identification data from ID memory
1. Press the identification key
. The ID1 data displayed.
2. Press
key for more than 2 seconds to enter the memory.
3. After the last used code shown [ ID1 :123 ], enter the ID memory code of the item.
4. Press
key to select the identification data, which is displayed for a while. The instrument returns
to the operation mode after loading the identification data. If there is any linked memory to the ID
memory, the linked memories are selected automatically.
5. Or press
key to return without any select.