FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
89
of
170
The nominal and limit value entry
1. Press the
key.
2. The current force following force changes to catch the peak appears on the display as [ FOLLOW:
100N ]. Enter the new value with numerical keys. Press the
key to save it or press
key to
return operation without saving.
3. The current decreasing rate to catch the intermediate peak values appears [ MID DECR : 25% ].
Enter new value with numerical keys. Press the
key to save it or press
key to return
operation without saving.
4. The current decreasing rate for ending the peak hold process appears [ END DECR : 80% ]. Enter
new value with numerical keys. Press the
key to save it or press
key to return operation
without saving.
5. The maximum force to stop testing is displayed [ STOP : 2000N ]. Enter new value with numerical
keys. Press the
key to save it or press
key to return operation without
6. The alarm output is activated at [ ALARM : 2500N ]. Enter new value with numerical keys. Press the
key to save it or press
key to return operation without saving.
7. The peak hold process is start if the load is heavier than [ EMPTY : 50N ] .Enter new value with
numerical keys.
8. Press the
key to return to the operation after saving the entry or press
key to go back
operation without saving the new empty range.
Product record into the SET memory
1. Press
key more than 2 seconds. [ MEMORY ] prompt appears.
2. Press
key. The last used Set memory code appears [ SET :001 ].
3. Enter the new memory code by pressing the numerical keys and press
key.
4. The previous follow value is shown on the display as [ SET 001: FOLLOW ], [ 5.00 N ]. Enter the new
value with numerical keys and press the
key.
5. The [ MID DECR : 20% ] prompt appears on the display. Enter new value with numerical keys. Press
the
key to save it or press
key to return operation without saving.
6. The [ END DECR : 50% ] prompt appears on the display. Enter new value with numerical keys. Press
the
key to save it or press
key to return operation without saving.
7. The [ STOP : 100,00 N ] prompt appears on the display. Enter new value with numerical keys. Press
the
key to save it or press
key to return operation without saving.
8. The [ ALARM : 150,00 N ] prompt appears on the display. Enter new value with numerical keys. Press
the
key to save it or press
key to return operation without saving.
9. The [ EMPTY : 1,00 N ] prompt appears on the display. Enter new value with numerical keys.
Press the
key to go to the following memory after save it or press
key to return operation
without saving.
Select product from SET memory
1. Press
key. The current minimum value to start the following force appears on the display as
[ FOLLOW: 100 N].
2. Press
key for more than 2 seconds to enter Set memory. The last used Set memory code
appears on the display as [ SET :001 ].
3. Enter the memory code of the product by pressing the numerical keys and press
key.
4. The selected product limits are loaded for usage after displaying values.
5. Or press
key to exit without saving.