FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
38
of
170
Minimum tare
You may restrict the taring by entering minimum tare value to the parameter 518. In case of activated
automatic taring, the instrument tares automatically if the loading is heavier than minimum tare.
Minimum weight for accurate weighing
The instrument produces data output or enables any feature, like printing, if the loading is heavier than
minimum weight. This feature increases the accuracy of your system.
Next verification date
The instrument warns the operator on the following verification or calibration date, if date is entered. The
warning is disappeared after pressing
key until switch on the instrument again.
Alibi Memory
RELATED PARAMETERS: Main block 8--.
You can fulfill your weight data recording obligations with the alibi memory in certified operation without having
paper archive. The weight data is saved into the alibi memory after every weighing operation together with
date and time. The alibi record number may also be found on the printout data.
The alibi memory recording principle is a loop memory. The oldest record will be deleted after the capacity
limit 99 999 was reached to overwrite the latest weighing. You can quickly access to the record of specific
weighing by entering the suitable search criteria.
Activating Alibi Memory
1. Go to the parameter [ 8-- METROLOGY] main block in set up.
2. Press key 2 times to access parameter 811.
3. Press
key after selecting YES in the parameter.
4. Press
key until [ SAVE : YES ] prompt appears on the display and press
key to save
the changes into the memory. [ E42 NEW ALIBI ] message appears.
5. Press
key to start Alibi memory.
How is the Data Recorded into the Alibi Memory?
After the following actions the transferred data is recorded into the alibi memory:
1. Press
key to print the label,
2. Automatic printing (automatic print data transferring),
3. Interface command ASCII < P >,
4. BSI commands which request the stable weight,
5. Print commands of fieldbus interfaces,
6. Digital < Print > input.
Recall Data from Alibi Memory
RELATED PARAMETERS: Parameter 813.
You may display the alibi record by selecting the criteria, which are alibi number, date, net weight, gross
weight or tare weight. You also may transfer alibi memory records to your PC.