FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019
Page
65
of
170
[ 523 MAX
:
] M Scale capacity Max and division (d)
MAX1/d1
MAX2/d2
MAX3/d3
Enter scale capacity and division after press
key.
Capacities and divisions of MR and MI scales are
entered as Max1, d1, Max2, d2, Max3, d3.
[ 524 OVER
: 9d
] M Limit of Indication
NO
1d
5d
9d
2%
5%
:
:
:
:
:
:
Over indication after Max
1 division more than Max
5 division more than Max
9 divisions more than Max
2% more than Max
5% more than Max
[ 525 TARETYPE
: SUB
] M Tare type.
SUB
ADD
:
:
Subtractive tare. Taring reduces the maximum net.
Additive tare. Taring is limited to Max Tare and Net
weighing is done up to Max.
[ 526 MAXTARE
: 0.0
]
M
Maximum tare at additive tare.
Enter the maximum tare of the scale which is written
on the marking label as;
T= + XXXX.X at additive tare
Default is 0.0 which means no limit.
53- DLC SETUP
]
DIGITAL LOAD CELL SETUP (Only FT-112D)
Press key or
key again to enter this menu.
Or press
key to go to the next sub-block.
[ 532 QUANTITY
: 01
] M Quantity of digital load cell
Enter the quantity of DLC used in the scale.
The quantity can be entered between 1 and 30.
[ 533 ADDRESSING
] M Addressing of digital load cells
Enter serial number after press
key.
[ 54- SHIFT ADJUST
]
SHIFT / ECCENTRICITY ADJUSTMENT (Only FT-112D)
Press key or
key again to enter this menu.
Press
key to return to beginning of the sub-block or press
key to enter the next main-block.
[ 541 METHOD
: CELL ] M Adjustment method
CELL
PAIR
:
:
Individual load cell shift adjust
Sectional pair shift adjustment
[ 542
AUTO
ADJUST
] M Automatic Eccentricity Adjustment
The eccentricity correction of scale is performed automatically
[ 543 MANUAL ADJUS
] M Manual Adjustment
The eccentricity correction of scale is performed manually.
[ 544 SET TO 1
: NO
] M Temporarily set shift constants to 1
NO
YES
:
:
Normal operation
(entered shift constants are used).
Test mode (shift constants are equal to 1).