background image

Kabelanschlusskasten Typ KP    Technisches Handbuch Rev. 1.01   September 2016 
Junction Box                Type KP  Technical Manual 

Seite / Page 6/8  

evtl. sich bildender Feuchtigkeit im Anschlusskasten belassen. Anschließend die Deckeldichtung auf Schmutz 
überprüfen und den Deckel mit dem Anschlusskasten gleichmäßig fest verschrauben. 

RIGHTS

 

AND

 

LIABILITIES 

 

All rights reserved. 

 

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by 
any means, mechanical, photocopying, recording, or otherwise, without the prior written permission of Flintec 
GmbH 

 

No patent liability is assumed with respect to the use of the information contained herein. While every 
precaution has been taken in the preparation of this book, FLINTEC assumes no responsibility for errors or 
omissions. Neither is any liability assumed for damages resulting from the use of the information contained 
herein. 

 

The information herein is believed to be both accurate and reliable. FLINTEC, however, would be obliged to 
be informed if any errors occur. FLINTEC cannot accept any liability for direct or indirect damages resulting 
from the use of this manual. 

 

FLINTEC reserves the right to revise this manual and alter its content without notification at any time. 

 

Neither FLINTEC nor its affiliates shall be liable to the purchaser of this product or third parties for damages, 
losses, costs, or expenses incurred by purchaser or third parties as a result of: accident, misuse, or abuse of 
this product or unauthorized modifications, repairs, or alterations to this product, or failure to strictly comply 
with FLINTEC operating and maintenance instructions. 

 

FLINTEC shall not be liable against any damages or problems arising from the use of any options or any 
consumable products other than those designated as Original FLINTEC Products. 

 

NOTICE: The contents of this manual are subject to change without notice. 

 
 

Copyright © 2007 by Flintec GmbH, 74909 Meckesheim, Bemannsbruch 9, Germany 

 

S

AFETY 

I

NSTRUCTIONS

 

 

 

CAUTION

 

READ this manual BEFORE operating or servicing this equipment. FOLLOW 

these instructions carefully. SAVE this manual for future reference. DO NOT allow untrained 
personnel to operate, clean, inspect, maintain, service, or tamper with this equipment. 
ALWAYS DISCONNECT this equipment from the power source before cleaning or performing 
maintenance. CALL FLINTEC ENGINEERING for parts, information, and service. 

 

 

WARNING 

ONLY PERMIT QUALIFIED PERSONNEL TO SERVICE THIS EQUIPMENT. 

EXERCISE CARE WHEN MAKING CHECKS, TESTS AND ADJUSTMENTS THAT MUST BE 
MADE WITH POWER ON. FAILING TO OBSERVE THESE PRECAUTIONS CAN RESULT 
IN BODILY HARM. 

 

 

WARNING 

FOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT 

TO PROPERLY GROUNDED OUTLET ONLY. DO NOT REMOVE THE GROUND PRONG. 

 

 

WARNING 

DISCONNECT ALL POWER TO THIS UNIT BEFORE REMOVING THE 

FUSE OR SERVICING. 

 

 

WARNING 

BEFORE CONNECTING/DISCONNECTING ANY INTERNAL ELECTRONIC  

COMPONENTS OR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT 
ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY (30) SECONDS BEFORE ANY 
CONNECTIONS OR DISCONNECTIONS ARE MADE. FAILURE TO OBSERVE THESE 
PRECAUTIONS COULD RESULT IN DAMAGE TO OR DESTRUCTION OF THE 
EQUIPMENT OR BODILY HARM. 

 

 

CAUTION 

OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE 

DEVICES. 

 

 

Summary of Contents for KP-4

Page 1: ...Kabel Anschlusskasten Junction Box Typ KP 4 Type KP 4 Technisches Handbuch Technical Manual Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www flintec com...

Page 2: ...chanische Installation 4 Elektrische Anschl sse 4 Anschluss der W gezellenkabel 4 Anschluss des Ausgangskabels 5 Eckenabgleich bei Waagen mit FLINTEC W gezellen 5 Table of contents RIGHTS AND LIABILIT...

Page 3: ...ngsanleitungen angefallen sind FLINTEC kann nicht haftbar gemacht werden f r Sch den oder Probleme die durch die Anwendung von Zubeh r oder anderen Verbrauchsg tern enstanden sind die nicht als origin...

Page 4: ...en herzustellen Potentialausgleich Die Anschlussreihenfolge der W gezellen sollte mit den Ecken der Waage bereinstimmen also Ecke 1 W gezelle 1 Ecke 2 W gezelle 2 usw ANSCHLUSS DER W GEZELLENKABEL Die...

Page 5: ...gehensweise 1 Die L tpunkte unmittelbar unterhalb der Kanalbezeichnung 1 4 sollen die L tst tzpunkte der sp ter einzubringenden Korrekturwiderst nde verbinden Auslieferungszustand Andernfalls w rden d...

Page 6: ...irs or alterations to this product or failure to strictly comply with FLINTEC operating and maintenance instructions FLINTEC shall not be liable against any damages or problems arising from the use of...

Page 7: ...e load cells should correspond to the corners of the scale i e Corner 1 Load cell 1 Corner 2 Load cell 2 etc LOAD CELL CABLE CONNECTION First the cable gland see 1 in fig 1 must be loosened Then you h...

Page 8: ...ignation 1 4 shall connect the solder joints for the resistors to be installed afterwards shipment status Otherwise the load cell will not get powered 9 Get the display value for each corner Use the h...

Reviews: