427-9030-01-12 Version 140
March 2018
7
1
D-Series Camera Installation
1.6
Location Considerations
The camera will require connections for power, video and communications. Ensure that cable
distances do not exceed the specifications and that cables adhere to all local and industry standards,
codes, and best practices. The D-Series camera should be mounted upright (ball up) or upside down
(ball down), depending on the model ordered. The camera should be mounted such that the FLIR logo
on the side of the camera is right-side up and readable.
A ball-up camera model can be mounted on top of the mounting surface. A ball-down camera model
can be mounted under an overhanging mounting arm, or underneath an overhanging mounting
surface such as eaves or an awning.
Note
If the camera is to be mounted on a pole or tower or other hard-to-reach location, connect and operate
the camera as a bench test at ground level prior to mounting the camera in its final location.
7.38
187.5
15.92
404.4
0.81
20.6
11.94
303.4
13.83
351.4
Cables (not shown)
exit at center of base
All dimensions are
in mm and (inches)
Cable Gland
Do not loosen
or remove