427-9030-01-12 Version 140
March 2018
8
1
D-Series Camera Installation
1.6.1
Prior to Cutting/Drilling Holes
When selecting a mounting location for the D-Series camera, consider cable lengths and cable routing.
Ensure the cables are long enough, given the proposed mounting locations and cable routing
requirements, and route the cables before you install the components.
Use cables that have sufficient dimensions to ensure safety (for power cables) and adequate signal
strength (for video and communications).
Caution!
1.7
Camera Mounting
The camera mount must nominally be rated to support at least 11.4 kg (25 lbs). For some installations,
the mount must support even greater weights. Use a mount which will provide adequate support in
adverse weather and environmental conditions. The D-Series camera can be secured to the mount
two ways:
•
1.5 in. NPT threaded coupler
Intended for rigid mounting with the supplied NPT stainless steel coupler, or equivalent.
Use PTFE pipe seal tape or equivalent on the coupler.
•
M5 x 0.8 fasteners (quantity 6)
If using four M5 x 0.8 fasteners, the maximum depth of the fastener should not exceed 10.0 mm
(0.394 in). Use Loctite 222 low strength threadlocker for the M5 fasteners.
Refer to the ICD for additional information (FLIR Doc. # 427-9XXX-XX-19).
There is no need to open the electronics enclosure. All settings and adjustments are done through
software. There are no user-serviceable parts inside the camera enclosure.
Figure 1-2: D-Series Camera Bottom Mounting Holes
(7.38)
187.5
square
(2.598)
66.00
bolt circle
60.0°
6X M5 X 0.8
equal spacing
10 mm (0.394 in.) max
fastener engagement
1-1/2 NPT
All dimensions are
in mm and (inches)