Enclosure
Double molded, waterproof (IP67)
Shock (Drop Test)
2 meters (6.5 feet)
Diode Test
Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical
Continuity Check
Audible signal will sound if the resistance is less than 100
Ω
(approx.), test
current <0.35mA
Input Impedance
>10M
Ω
VDC & >10M
Ω
VAC
AC Response
Average responding
ACV Bandwidth
40Hz to 1kHz
Crest Factor
≤
3 at full scale up to 500V, decreasing linearly to
≤
1.5 at 1000V
Display
6,000 count backlit liquid crystal with bargraph
Overrange indication
“
OL
” is displayed
Auto Power Off
15 minutes (approximately) with disable feature
Polarity
Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate
2 times per second, nominal
Low Battery Indication “ ”
is displayed if battery voltage drops below operating voltage
Battery
One 9 volt (NEDA 1604) battery
Fuses
mA, µA ranges; 0.8A/1000V ceramic fast blow
A range; 10A/1000V ceramic fast blow
Operating Temperature
5
°
C to 40
°
C (41
°
F to 104
°
F)
Storage Temperature
-20
°
C to 60
°
C (-4
°
F to 140
°
F)
Operating Humidity
Max 80% up to 31
°
C (87
°
F) decreasing linearly to 50% at 40
°
C (104
°
F)
Storage Humidity
<80%
Operating Altitude
2000meters (7000ft) maximum.
Weight
342g (0.753lb) (includes holster).
Size
187 x 81 x 50mm (7.36” x 3.2” x 2.0”) (includes holster)
Safety
This meter is intended for origin of installation use and protected, against
the users, by double insulation per EN61010-1 and IEC61010-1 2
nd
Edition
(2001) to Category IV 600V and Category III 1000V; Pollution Degree 2.
The meter also meets UL 61010-1, 2
nd
Edition (2004), CAN/CSA C22.2 No.
61010-1 2
nd
Edition (2004), and UL 61010B-2-031, 1
st
Edition (2003)
Approvals