16.2.4.3
Commented infrared images
This section includes a few typical infrared images of moisture problems on commercial
& residential façades.
Comment
Infrared image
Improperly terminated and sealed stone veneer to
window frame and missing flashings has resulted
in moisture infiltration into the wall cavity and inte-
rior living space.
10554703;a1
Moisture migration into drywall from capillary drive
and interior finish components from inadequate
clearance and slope of grade from vinyl siding
façade on an apartment complex.
10554803;a1
16.2.5
Moisture detection (3): Decks & balconies
16.2.5.1
General information
Although there are differences in design, materials and construction, decks—plaza
decks, courtyard decks etc—suffer from the same moisture and leaking problems as
low-slope commercial roofs. Improper flashing, inadequately sealed membranes,
and insufficient drainage may lead to substantial damage in the building structures
below.
Balconies, although smaller in size, require the same care in design, choice of mate-
rial, and workmanship as any other building structure. Since balconies are usually
supported on one side only, moisture leading to corrosion of struts and concrete re-
inforcement can cause problems and lead to hazardous situations.
Publ. No. T559382 Rev. a358 – ENGLISH (EN) – June 23, 2009
59
16 – Introduction to building thermography