background image

Operation

AC or DC Voltage Measurement

1. Set the function switch to the “

AC/DCV

” position

2. Press the SELECT button to select AC or DC voltage

measurement

3. Touch the test probe tips to the circuit under test. Be sure to

observe the correct polarity (red lead to positive, black lead to

negative).

4. Read the voltage on the display

Resistance/Continuity Measurement

WARNING:

To avoid electric shock, disconnect power to the unit

under test and discharge all capacitors before taking any

resistance measurements. Remove the batteries and unplug the

line cords. Never measure continuity on circuits or wires that

have voltage on them.

1.  S et the function switch to the “ Ω       

)))     ” position. 

2. Connect the test leads to the circuit to be measured.

3. Read the value on the display.

4. For Continuity tests, press the SELECT button until the “

)))“

symbol appears in the display.

5. If the resistance is less than 60 ohms, an audible tone will sound.

Capacitance Measurement

WARNING:

To avoid electric shock, disconnect power to the unit

under test and discharge all capacitors before taking any

capacitance measurements. Remove the batteries and unplug

the line cords. Never measure continuity on circuits or wires that

have voltage on them.

1.  S et the function switch to the “ Ω      

)))     ” position. 

2. Press the SELECT button until “nF” appears in the display.

3. Press the RELATIVE button to zero the display

4. Connect the test leads to the capacitor to be measured.

5. Read the value on the display.

Diode Test

WARNING:

To avoid electric shock, do not test any diode that

has voltage on it.

1.  S et the function switch to “ Ω      

)))

“position.

2. Press the SELECT button once to enter Diode Test. The “ “

symbol will appear in the display.

3. Touch the test probe tips to the diode or semiconductor junction

you wish to test. Note the meter reading.

4. Reverse the test lead polarity by reversing the red and black

leads. Note this reading.

5. The diode or junction can be evaluated as follows:

A. If one reading shows a value and the other reading shows OL,

the diode is good.

B. If both readings show OL, the device is open.

C. If both readings are very small, or 0, the device is shorted

AC/DC Current Measurement

1. Set the function switch to the “

mA AC/DC

” position.

2. Press the SELECT button to measure AC or DC mA.

3. Remove power from the circuit under test and open the circuit at

the point where you wish to measure current.

4. Touch the black test probe tip to the negative side of the circuit

and touch the red test probe tip to the positive side of the circuit.

5. Apply power to the circuit.

6. Read the value on the display

Frequency/Duty Cycle Measurement

1. Set the function switch to the “

HZ/DUTY”

position.

2. Press the Hz/DUTY button once to display Duty Cycle %. Pressing

the button again will toggle the display to frequency (Hz).

3. Touch the test probe tips to the circuit under test. Be sure to

observe the correct polarity (red lead to positive, black lead to

negative).

4. Read the value on the display.

Features

Relative Button

The relative measurement feature allows you to make measurements

relative to a stored reference value. A reference voltage can be

stored and measurements made in comparison to that value. The

displayed value is the difference between the reference value and the

measured value.
1. Perform the measurement as described in the operating

instructions.

2. Press the RELATIVE button to store the reading in the display and

the "REL" indicator will appear on the display.

3. The display will now indicate the difference between the stored

value and the measured value.

4. Press the RELATIVE button to exit the relative mode.

Note:

The Relative function does not operate in the Frequency

function.

Data Hold Button

The Data Hold function allows the meter to “freeze” a measurement

for later reference

1. Press the “

DATA HOLD

” button to “freeze” the display, the

HOLD

” indicator will appear.

2. Press the “

DATA HOLD

” button to return to normal operation.

Auto Power Off

1. To save power, the display automatically turns off in 30 minutes.

2. Press the SELECT button to turn display back on.

3. To cancel Auto Power Off, set the function switch to the off

position. Hold down the SELECT button and turn the function

switch to the desired position and release the SELECT button after

3 seconds.

Maintenance

WARNING

: To avoid electric shock, disconnect the test leads

from any source of voltage before removing the battery cover.

WARNING:

To avoid electric shock, do not operate your meter

until the battery cover is in place and fastened securely.

This MultiMeter is designed to provide years of dependable service, if

the following guidelines are followed:

1.

KEEP THE METER DRY

. If it gets wet, wipe it off.

2.

USE AND STORE THE METER IN NORMAL

TEMPERATURES.

Temperature extremes can shorten the life of

the electronic parts and distort or melt plastic parts.

3.

HANDLE THE METER GENTLY AND CAREFULLY.

Dropping it

can damage the electronic parts or the case.

4.

KEEP THE METER CLEAN.

Wipe the case occasionally with a

damp cloth. DO NOT use chemicals, cleaning solvents, or

detergents.

5.

USE ONLY FRESH BATTERIES OF THE RECOMMENDED

SIZE AND TYPE.

Remove old or weak batteries so they do not

leak and damage the unit.

6.

IF THE METER IS TO BE STORED FOR A LONG PERIOD OF

TIME

, the batteries should be removed to prevent damage to the

unit.

WARNING

: Disconnect the test leads from any source of voltage

before removing the back cover or the battery/fuse door. Do not

operate your meter until the rear housing is in place and fastened

securely.

Replacing the Battery

1. Remove the rubber holster (if in place)

2. Remove Philips head screw and lift off the rear housing of the

meter.

3. Replace old battery with fresh CR2032 type button battery.

4. Replace the rear cover and secure the screw.

You, as the end user, are legally bound (

Battery

ordinance

) to return all used batteries and

accumulators;

disposal in the household garbage is

prohibited!

You can hand over your used batteries / accumulators

at collection points in your community or wherever

batteries / accumulators are sold!

Disposal:

Follow the valid legal stipulations in respect

of the disposal of the device at the end of its lifecycle

more infor for 

Extech DM110

Phone: 01235 838 555

Email: cs@airconcern.co.uk

Web. www.airconcern.co.uk

Air Concern Ltd, Building 173 Curie Avenue Harvell Didcot, Oxfordshire

Reviews: