14             MM560A-MM570A-EU-EN 

V1.1 8/12 

PC-COMM computer interface capabilities 

The instrument equips with an optical isolated interface port at the meter back for data communication. 
The optional PC interface kit is required to connect the meter to the PC computer. The software 
features a digital display, an analog display, a comparator and a Data Graphical recorder display. 
Refer to the README file in the interface kit for further details. 

 
MAX/MIN RECORDING mode 

Press 

REC

 button momentarily to activate MAX/MIN recording mode. The LCD annunciators “R” and 

“MAX MIN”

 

turn on. The meter beeps when new maximum or minimum reading is updated. Press the 

button momentarily to read throughout the Maximum (MAX), Minimum (MIN), and Maximum minus 
Minimum (MAX-MIN) readings. Press the button for 1 second or more to exit MAX/MIN recording 
mode. Auto Power Off feature will be disabled automatically in this mode. 
 

PEAK

 

Capture  

Press the 

PEAK

 button momentarily to activate PEAK mode to capture voltage or current signal 

duration as short as 0.8ms. This mode is available in DC, AC, DC+AC modes of voltage and current 
functions. The LCD annunciators “C” & “MAX”

 

turn on. The meter beeps when new maximum or 

minimum reading is updated. Press the button momentarily to read throughout the Maximum (MAX), 
Minimum (MIN), and Maximum minus Minimum (MAX-MIN) readings. Press the button for 1 second or 
more to exit PEAK capture mode. Auto Power Off feature will be disabled automatically in this mode. 
 

 

Relative Zero mode 

Relative Zero allows the user to offset the meter consecutive measurements with the displaying 
reading as the reference value. Practically MAX/MIN recording feature readings can also be set as 
relative reference value. Press the 

 button momentarily to activate and to exit Relative Zero 

mode. 
 

500000 high resolution mode 

In DC voltage and frequency functions, press the 

500000

 button momentarily to toggle between the 

4-4/5 digits fast mode and the 5-4/5 digits high resolution mode. 
 

Summary of Contents for Extech Instruments MultiMaster MM560A

Page 1: ...User s Guide MultiMaster Digital MultiMeter Series With PC Interface Models MM560A MM570A A...

Page 2: ...EC61010 1 2nd Ed 2001 Measurement Category Measurement Category IV CAT IV is for measurements performed at the source of the low voltage installation Examples are electricity meters and measurements o...

Page 3: ...ction fuse Do not attempt a current measurement to any circuit where the open circuit voltage is above the protection fuse voltage rating Suspected open circuit voltage should be checked with voltage...

Page 4: ...special functions features 3 Selector to turn the Power On or Off and Select a function 4 Input Jack for 10A 20A for 30sec current and for T2 function 5 Input Jack for all functions EXCEPT current A m...

Page 5: ...and can responds accurately to the total effective RMS value regardless of the waveform Distorted waveforms with the presence of DC components and harmonics may cause 1 Overheated transformers generat...

Page 6: ...AC Voltage press SELECT button momentarily to toggle between AC and dBm In DC Voltage press SELECT button momentarily to toggle between DC and DC AC In mV Voltage press SELECT button momentarily to s...

Page 7: ...s recommended to first measure the signal voltage or current level then activate the Hz function in that voltage or current range to automatically get the most appropriate trigger level When activated...

Page 8: ...ll be saved automatically to the non volatile memory as power up default Press 500000 button momentarily to toggle between 5 full digits and 6 full digits Hz readings A A A Note Unlike the Line Level...

Page 9: ...n C and F readings and the new setting will be saved automatically in the non volatile memory as power up default Press T1 T2 RANGE button momentarily to select T1 T2 or T1 T2 readings Note Insert the...

Page 10: ...ile memory as power up default Continuity function is convenient for checking wiring connections and operation of switches A continuous beep tone indicates a complete wire A A CAUTION Using resistance...

Page 11: ...ing any measurement Large value capacitors should be discharged through an appropriate resistance load A A A Note Normal forward voltage drop forward biased for a good silicon diode is between 0 400V...

Page 12: ...12 MM560A MM570A EU EN V1 1 8 12 other readings indicate the diode is resistive or shorted defective...

Page 13: ...e value It is set at 4mA 0 zero and 20mA 100 span with 0 01 high resolution which virtually extends the meters capability to test and regulate the externally powered loop current in the industrial pro...

Page 14: ...in this mode PEAK Capture Press the PEAK button momentarily to activate PEAK mode to capture voltage or current signal duration as short as 0 8ms This mode is available in DC AC DC AC modes of voltage...

Page 15: ...continuity and Jack Beep input warning features remain Beep Jack Input Warning The meter beeps as well as displays InErr to warn the user against possible damage to the meter due to improper connecti...

Page 16: ...end it for re calibration Refer to the WARRANTY section for obtaining warranty or repair service Trouble Shooting If the instrument fails to operate check battery fuses leads etc and replace as necess...

Page 17: ...t input 11A 1000V IR 20kA or better F fuse DMM B 11A Battery replacement Loosen the 2 screws from the battery access door of the case bottom Lift the battery access door and thus the battery compartme...

Page 18: ...10 1 2nd Ed CAN CSA C22 2 No 61010 1 0 92 to Category III 1000V AC DC and Category IV 600V AC DC MM560A Terminals to COM Measurement Category V Category III 1000 Vac Vdc and Category IV 600 Vac Vdc A...

Page 19: ...4A JIS6AM6 or IEC6LF22 Power Consumption 6mA typical Low Battery Below approx 7V APO Timing Idle for 17 minutes APO Consumption 55 A typical for MM560A 30 A typical for MM570A Dimension L186mm X W87mm...

Page 20: ...500 00 MV 5 0000V 50 000V 0 02 2D 0 03 2D 500 00V 0 04 2D 0 05 2D 1000 0V 0 05 2D 0 1 2D NMRR 60DB 50 60HZ CMRR 120DB DC 50 60HZ RS 1K Input Impedance 10M 30pF nominal 80pF nominal for 500mV range Oh...

Page 21: ...d 300Hz 1kHz 1 0 40d 5kHz 20kHz 1kHz 20kHz 500 00mV 0 5 20d 1dB 5 0000V 50 000V 0 8 20d 2dB 500 00V 0 5 20d 3dB 1000 0V Unspecified Unspecified 20kHz 100kHz 20kHz 100kHz 500 00mV 2 5 40d 5 0000V 50 00...

Page 22: ...000A 45mV A 10 000A 0 5 50d 1 0 40d 45mV A 40Hz 1kHz 500 00 A 0 15mV A 5000 0 A 0 15mV A 50 000mA 3 3mV mA 500 00mA 3 3mV mA 5 0000A 45mV A 10 000A 0 7 50d 1 0 40d 45mV A 1kHz 10kHz 500 00 A 0 15mV A...

Page 23: ...3d kHz 2d Input Frequency 5Hz 500 kHz 5V Logic Family Diode Tester Range Accuracy Test Current Typical Open Circuit Voltage 5 0000V 1 1d 0 4mA 3 5 VDC Capacitance RANGE Accuracy 50 00nF 0 8 3d 500 0n...

Page 24: ...24 MM560A MM570A EU EN V1 1 8 12 ISO 9001 Certified...