427-0033-00-12 Version 110
February 2019
12
This document does not contain any export-controlled information.
F
-
Series ID Camera Installation
camera. If power is supplied to it, the camera will be in one of two modes: Booting Up or Powered
On.
The power cable supplied by the installer must use wires that are sufficient size gauge (16 AWG
recommended) for the supply voltage and length of the cable run, to ensure adequate current
carrying capacity. Always follow local building codes.
Ensure the camera is properly grounded. Typical to good grounding practices, the camera chassis
ground should be connected to the lowest resistance path possible. FLIR requires a grounding strap
anchored to the grounding lug on the back plate of the camera housing and connected to the nearest
earth-grounding point.
Note
1.4.2
Video Connection
The analog video connection on the back of the camera is a BNC connector. The camera also
provides an RCA video connector that can be used to temporarily monitor the video output, without
disconnecting the BNC connection.
The video cable used should be rated as RG59U or better to ensure a quality video signal.
1.4.3
GPIO Alarm Connections
The camera can receive a single input signal and can provide a single output signal.
1.4.4
Ethernet Connection
The cable gland seal is designed for use with Shielded Category 6 Ethernet cable.
The terminal blocks for power connections will accept a maximum 16 AWG wire size.
Figure 1-5: GPIO Terminal Plug
Table 1-1: GPIO Connections - J102A
Pin
Connection
Notes
1
Alarm Out1
Relay contact
rated load 0.09 A @ 5 Vdc
2
Alarm Out2
3
GND
4
Alarm In1 –
Dry alarm contact
5
Alarm In2 +
1
5
2
3
4