For full details, refer to the related section of this guide.
intelliRock Reader Setup
1. Power on the intelliRock reader
2. Select the “Setup” (F5) menu option
3. Use the function keys to access and complete reader setup options:
• F1: set display for either PSI or MPa
• F2: set the time and date
• F3: toggle the clock display between 12 and 24-hour mode
• F4: set temperature scales
• F5: access secondary menus
Starting an intelliRock Logger
1. Connect the logger to the intelliRock reader by attaching the logger wires to the termi-
nals on the reader.
2. Power the reader on, or if it is already on, wait for it to establish connection with the log-
ger. For a new logger, the “Run Status” will display “Not Running”.
3. Select the “Logger” (F1) menu option, then the “Start” (F1) menu option.
4. Use the function keys to step through the logger setup screens, making the desired en-
tries for Job Name, Datum, Maturity Method, and Logger Location.
5. After completing logger setup, select the “Save” (F1) menu option to start the logger. The
logger display screen will indicate a “Run Status” of “Running” during the first 60 min-
utes after logger startup, or “Running Locked” after 60 minutes has elapsed.
Reviewing Logger Data
1. Power the reader on.
2. Connect the logger you wish to review to the reader.
3. After a few seconds, the logger data display screen will appear. If the “psi” display is
zero, it typically means that no calibration mix has yet been associated with the logger.
Consult with the project engineer to know which calibration mix to select to view psi data
for any logger.
4. To associate a calibration mix with the logger, from the logger data display screen select
the “Mix” (F2) menu option. Note: calibration mix curves are uploaded to the reader via
the intelliRock Uploader software.
5. To view a graph of the logger data, select the “Logger” (F1) menu option.
6. The message “Data ready to be read” will appear on the screen. From this screen, select
the “Read” (F4) menu option.
7. A progress bar will appear on the screen, followed by a message, “Logger download
complete” indicating a successful data transfer to the reader.