27
intelliRock technical support:
Visit www.flir.com/support or call (866) 276-8369, 9am - 5pm, EST
The text above the F1 key is a logger status message that will indicate either “Locked” or “Re-
set”:
• “Locked” means that the logger can no longer be stopped and restarted.
• “Reset” will only appear within the first hour of logger activation and indicates that the
user can stop and restart the logger.
Select the “Read” (F4) menu option to have the reader transfer the data from the logger to the
reader. Press F5 to return to the previous screen.
After pressing the F4 key to read the logger data, a progress bar will briefly appear on the
screen, followed by the confirmation message shown in Figure 4.14.
Figure 4.14: Confirmation message that logger data was transferred to the reader.
This message confirms that the logger data is stored on the reader. When convenient, use the
intelliRock PC software to transfer the data from the reader to the intelliRock cloud software to
enable sharing of data and report generation. Refer to the “intelliRock PC Software” section of
this guide for instructions on getting logger data into the cloud.
The options available to the user from the “Logger download complete” screen are:
• Notes (F3): enter notations related to logger data.
• Graph (F4): view a graph of the logger data.
• Menu (F5): return to the main menu
Entering Logger Data Notes
Loggers can store text notes about conditions and events. For example, a user may wish to
indicate that post-tensioning will occur based on a reading, or that conditions are right to do
the next pour, or to remove forms. To enter notes, press the F3 key. If there are no notes stored
on the logger, the reader will display the message, “No notes are present on this logger.” To add
a note to the logger, select the New (F4) menu option, which will open the notes entry screen
shown in Figure 4.15.